Literature DB >> 16631654

Results of the prospective multicenter trial of robotically assisted totally endoscopic coronary artery bypass grafting.

Michael Argenziano1, Marc Katz, Johannes Bonatti, Sudhir Srivastava, Douglas Murphy, Robert Poirier, Didier Loulmet, Leland Siwek, Usha Kreaden, David Ligon.   

Abstract

BACKGROUND: Robotic technology has been proven safe and efficacious in the performance of mitral valve repair and atrial septal defect repair. This report describes a Food and Drug Administration-sanctioned multicenter study of the safety and efficacy of the da Vinci system (Intuitive Surgical, Inc, Mountain View, CA) for totally endoscopic coronary artery bypass (TECAB) surgery.
METHODS: Patients requiring left anterior descending (LAD) coronary artery revascularization were eligible. The procedure was performed with femoro-femoral cardiopulmonary bypass (CPB), endoaortic balloon occlusion, and thoracoscopy. All aspects of the procedure were performed with the robotic system, from internal mammary artery harvest to coronary anastomosis.
RESULTS: Ninety-eight patients requiring single-vessel LAD revascularization were enrolled at 12 centers. Thirteen patients (13%) were excluded intraoperatively (eg, failed femoral cannulation, inadequate working space). In 85 patients (69 men, age 58 +/- 10 years) who underwent TECAB, CPB time was 117 +/- 44 minutes, cross-clamp time was 71 +/- 26 minutes, and hospital length of stay was 5.1 +/- 3.4 days. There were five (6%) conversions to open techniques. There were no deaths or strokes, one early reintervention, and one myocardial infarction (1.5%). Three-month angiography was performed in 76 patients, revealing significant anastomotic stenoses (> 50%) or occlusions in 6 patients. Overall freedom from reintervention or angiographic failure was 91%.
CONCLUSIONS: Robotic TECAB was accomplished with no mortality, low morbidity, and angiographic patency and reintervention rates comparable with published data. Although the use of CPB was a limitation of the technique, this experience represents a step toward more advanced procedures, such as multivessel or off-pump TECAB.

Entities:  

Mesh:

Year:  2006        PMID: 16631654     DOI: 10.1016/j.athoracsur.2005.11.007

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  30 in total

Review 1.  Advances in surgical treatment of acute and chronic coronary artery disease.

Authors:  William E Cohn
Journal:  Tex Heart Inst J       Date:  2010

2.  Design of an Algorithm for Automated, Computer-Guided PASI Measurements by Digital Image Analysis.

Authors:  Christine Fink; Tobias Fuchs; Alexander Enk; Holger A Haenssle
Journal:  J Med Syst       Date:  2018-11-03       Impact factor: 4.460

3.  Cost effectiveness analysis of minimally invasive internal thoracic artery bypass versus percutaneous revascularisation for isolated lesions of the left anterior descending artery.

Authors:  Christopher Rao; Omer Aziz; Sukhmeet Singh Panesar; Catherine Jones; Stephen Morris; Ara Darzi; Thanos Athanasiou
Journal:  BMJ       Date:  2007-03-02

4.  A consensus document on robotic surgery.

Authors:  D M Herron; M Marohn
Journal:  Surg Endosc       Date:  2007-12-28       Impact factor: 4.584

5.  Revascularization treatment in patients with coronary artery disease.

Authors:  S G Foussas; G Z Tsiaousis
Journal:  Hippokratia       Date:  2008-01       Impact factor: 0.471

Review 6.  Robotically assisted totally endoscopic coronary artery bypass surgery.

Authors:  Leonardo Secchin Canale; Stephanie Mick; Tomislav Mihaljevic; Ravi Nair; Johannes Bonatti
Journal:  J Thorac Dis       Date:  2013-11       Impact factor: 2.895

7.  Factors causing prolonged mechanical ventilation and peri-operative morbidity after robot-assisted coronary artery bypass graft surgery.

Authors:  Huan Hsu; Hui-Chin Lai; Tsun-Jui Liu
Journal:  Heart Vessels       Date:  2018-07-13       Impact factor: 2.037

Review 8.  Robotic surgery: review of the latest advances, risks, and outcomes.

Authors:  Mary Downes Gastrich; Joseph Barone; Gloria Bachmann; Mark Anderson; Adrian Balica
Journal:  J Robot Surg       Date:  2011-01-21

9.  Initial experience with internal mammary artery harvesting with the da Vinci Surgical System for minimally invasive direct coronary artery bypass.

Authors:  Tomoyuki Fujita; Hiroki Hata; Yusuke Shimahara; Shunsuke Sato; Junjiro Kobayashi
Journal:  Surg Today       Date:  2014-01-15       Impact factor: 2.549

10.  Risk of renal dysfunction after less invasive multivessel coronary artery bypass grafting.

Authors:  Soroosh Kiani; Alex K Brown; Dinesh J Kurian; Stanislav Henkin; Mary M Flynn; Nannan Thirumavalavan; Pranjal H Desai; Robert S Poston
Journal:  Innovations (Phila)       Date:  2012 May-Jun
View more