Computed tomography versus magnetic resonance imaging of endoleaks after EVAR.

M J van der Laan1, L W Bartels, M A Viergever, J D Blankensteijn.   

Abstract

AIM: The aim of study was to compare the sensitivity of MRI and CTA for endoleak detection and classification after EVAR. PATIENTS &
METHODS: Twenty-eight patients, between 2 days and 65 months after EVAR, were evaluated with both CT and MRI. Twenty-five patients had an Ancure graft and the other three had an Excluder. The MRI protocol for endoleak evaluation included: a T1-weighted spin echo, a high-resolution 3D CE-MRA, and a post-contrast T1-weighted spin echo. In total 40 ml Gadolinium was administered. The CT protocol consisted of a blank survey followed by a spiral CT angiography (CTA) using 140 ml of Ultravist. An experienced, blinded observer evaluated all CTs and MRIs.
RESULTS: Using MRI and MRA techniques significantly more endoleaks (23/35) were detected than with CTA (11/35) (p=0.01, Chi-Square). CT could not determine the type of endoleak in 3 of the 11 endoleaks detected and was uncertain in one. MRI was uncertain about the type in 14 of the 23 endoleaks detected. All endoleaks visible on CT were visible by MRI as well.
CONCLUSIONS: MRI techniques are more sensitive for the detection of endoleak after endovascular AAA repair than CT.

Entities:  

Mesh:

Year:  2006        PMID: 16630731     DOI: 10.1016/j.ejvs.2006.02.011

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  9 in total

1.  Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair.

Authors:  Vitaliano Buffa; Antonio Solazzo; Valeria D'Auria; Alessandra Del Prete; Andrea Vallone; Monica Luzietti; Manuela Madau; Roberto Grassi; Vittorio Miele
Journal:  Radiol Med       Date:  2014-07-02       Impact factor: 3.469

2.  "Sweet spot" for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT.

Authors:  Katherine E Maturen; Ravi K Kaza; Peter S Liu; Leslie E Quint; Shokoufeh H Khalatbari; Joel F Platt
Journal:  J Comput Assist Tomogr       Date:  2012 Jan-Feb       Impact factor: 1.826

Review 3.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

4.  Imaging Surveillance following Endovascular Aneurysm Repair.

Authors:  Anand Shah; S William Stavropoulos
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

5.  Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms.

Authors:  Mario Alerci; Michel Oberson; Antonella Fogliata; Augusto Gallino; Peter Vock; Rolf Wyttenbach
Journal:  Eur Radiol       Date:  2008-12-23       Impact factor: 5.315

Review 6.  Surveillance of patients post-endovascular aneurysm repair.

Authors:  P Sharma; C Kyriakides
Journal:  Postgrad Med J       Date:  2007-12       Impact factor: 2.401

7.  Abdominal aortic aneurysm: Treatment options, image visualizations and follow-up procedures.

Authors:  Zhong-Hua Sun
Journal:  J Geriatr Cardiol       Date:  2012-03       Impact factor: 3.327

8.  Utility of Noncontrast Magnetic Resonance Angiography for Aneurysm Follow-Up and Detection of Endoleaks after Endovascular Aortic Repair.

Authors:  Hiroshi Kawada; Satoshi Goshima; Kota Sakurai; Yoshifumi Noda; Kimihiro Kajita; Yukichi Tanahashi; Nobuyuki Kawai; Narihiro Ishida; Katsuya Shimabukuro; Kiyoshi Doi; Masayuki Matsuo
Journal:  Korean J Radiol       Date:  2020-12-21       Impact factor: 3.500

9.  What is the role of contrast-enhanced ultrasound in the evaluation of the endoleak of aortic endoprostheses? A comparison between CEUS and CT on a widespread scale.

Authors:  E David; V Cantisani; H Grazhdani; L Di Marzo; L Venturini; F Fanelli; M Di Segni; N Di Leo; L Brunese; F Calliada; M Ciccariello; A Bottari; G Ascenti; F D'Ambrosio
Journal:  J Ultrasound       Date:  2016-11-23
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.