BACKGROUND: The aim of this study was to assess the accuracy of stress 99m technetium tetrofosmin myocardial perfusion imaging for the diagnosis of in stent stenosis (ISS). METHODS: We studied 72 patients who underwent exercise or dobutamine stress 99m technetium tetrofosmin imaging, 0.9+/-0.5 years after percutaneous coronary interventions in which stents were deployed. Coronary angiography was performed within 3 months of the stress test. ISS was defined as > or =50% stenosis in a coronary segment with previous stenting. Significant coronary artery disease (CAD) was defined as > or =50% stenosis within or outside the stented coronary segment. RESULTS: The stent was deployed in 1 coronary artery in 52 patients, and in 2 coronary arteries in 20 patients (a total of 92 detected in 42 (58%) patients (51 stents). Reversible perfusion abnormalities were present in 34 of patients with ISS (sensitivity=81%, CI 70-94). Regional sensitivity for diagnosis of stenosis per stent was 76% (CI 65-88), specificity was 83% (CI 71-94) and accuracy was 79% (CI 69-85). Reversible perfusion abnormalities were detected in > or =2 vascular distributions in 15 of 22 patients with multi-vessel CAD and in 5 of 50 patients without (sensitivity for identifying multivessel CAD=68%, CI 50-89; specificity=90%, CI 82-98; and accuracy=83%, CI 75-90). CONCLUSION: Stress 99m technetium tetrofosmin myocardial perfusion imaging is a useful non-invasive technique for the diagnosis of in stent stenosis and extent of CAD in patients with previous percutaneous coronary artery interventions.
BACKGROUND: The aim of this study was to assess the accuracy of stress 99m technetium tetrofosmin myocardial perfusion imaging for the diagnosis of in stent stenosis (ISS). METHODS: We studied 72 patients who underwent exercise or dobutamine stress 99m technetium tetrofosmin imaging, 0.9+/-0.5 years after percutaneous coronary interventions in which stents were deployed. Coronary angiography was performed within 3 months of the stress test. ISS was defined as > or =50% stenosis in a coronary segment with previous stenting. Significant coronary artery disease (CAD) was defined as > or =50% stenosis within or outside the stented coronary segment. RESULTS: The stent was deployed in 1 coronary artery in 52 patients, and in 2 coronary arteries in 20 patients (a total of 92 detected in 42 (58%) patients (51 stents). Reversible perfusion abnormalities were present in 34 of patients with ISS (sensitivity=81%, CI 70-94). Regional sensitivity for diagnosis of stenosis per stent was 76% (CI 65-88), specificity was 83% (CI 71-94) and accuracy was 79% (CI 69-85). Reversible perfusion abnormalities were detected in > or =2 vascular distributions in 15 of 22 patients with multi-vessel CAD and in 5 of 50 patients without (sensitivity for identifying multivessel CAD=68%, CI 50-89; specificity=90%, CI 82-98; and accuracy=83%, CI 75-90). CONCLUSION: Stress 99m technetium tetrofosmin myocardial perfusion imaging is a useful non-invasive technique for the diagnosis of in stent stenosis and extent of CAD in patients with previous percutaneous coronary artery interventions.
Authors: S C Smith; J T Dove; A K Jacobs; J W Kennedy; D Kereiakes; M J Kern; R E Kuntz; J J Popma; H V Schaff; D O Williams; R J Gibbons; J P Alpert; K A Eagle; D P Faxon; V Fuster; T J Gardner; G Gregoratos; R O Russell; S C Smith Journal: J Am Coll Cardiol Date: 2001-06-15 Impact factor: 24.094
Authors: E Tadamura; H Iida; K Matsumoto; M Mamede; S Kubo; H Toyoda; T Shiozaki; T Mukai; Y Magata; J Konishi Journal: J Am Coll Cardiol Date: 2001-01 Impact factor: 24.094
Authors: Michael J Zellweger; Markus Weinbacher; Andreas W Zutter; Raban V Jeger; Jan Mueller-Brand; Christoph Kaiser; Peter T Buser; Matthias E Pfisterer Journal: J Am Coll Cardiol Date: 2003-07-02 Impact factor: 24.094
Authors: Abdou Elhendy; Arend F l Schinkel; Ron T van Domburg; Jeroen J Bax; Roelf Valkema; Don Poldermans Journal: J Nucl Cardiol Date: 2003 Nov-Dec Impact factor: 5.952
Authors: Piet K Vanhoenacker; Isabel Decramer; Olivier Bladt; Giovanna Sarno; Erik Van Hul; William Wijns; Ben A Dwamena Journal: BMC Med Imaging Date: 2008-07-31 Impact factor: 1.930
Authors: Pengfei Zhang; Song Chen; Yang Li; Qiuhong Du; Lijuan Wang; Yingxian Sun; Yaming Li Journal: Exp Ther Med Date: 2016-11-04 Impact factor: 2.447