Literature DB >> 16628029

Optimal delay time for the hepatic parenchymal enhancement at the multidetector CT examination.

Yong Eun Chung1, Ki Whang Kim, Joo Hee Kim, Joon Seok Lim, Young Taik Oh, Jae-Joon Chung, Myeong-Jin Kim.   

Abstract

The objective of this study was to determine the optimal scan delay time after hepatic parenchymal enhancement using a 16-channel multidetector row helical CT (MDCT) scanner. Two hundred fifty-five consecutive patients underwent biphasic CT scans using a 16-channel MDCT. In group A (n = 125), two hepatic venous phase scans (HVP1 and HVP2) were obtained at 40 and 60 seconds, after 100-HU threshold time (T100HU) in the abdominal aorta. In group B (n = 130), HVP1 and HVP2 scans were obtained 50 and 70 seconds after T100HU. Both groups were divided into subgroups that were given different contrast media. Groups A1 and B1 received a contrast medium of 300 mgI/mL; groups A2 and B2 received a contrast medium of 370 mgI/mL. Each patient was injected with contrast medium at a dose of 2 mL/kg at a rate adjusted to the patient's body weight with a constant injection duration of 47 seconds. The attenuation values (HU) for the liver, portal vein, hepatic vein, and aorta were measured. The average HU was compared between the groups. Hepatic enhancement in the images obtained at 50 and 60 seconds after T100HU was greater (P < 0.05) than in images obtained at 40 and 70 seconds. These results were obtained with both contrast media. A few patients showed greater enhancement at a 40 seconds or 70 seconds. Hepatic enhancement was significantly greater in all scans using a contrast medium dose of 370 mgI/mL compared with the 300-mgI/mL dose (P < 0.05). Independent of the concentration of contrast medium, scan delays of 50 to 60 seconds after T100HU may provide optimal hepatic enhancement.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16628029     DOI: 10.1097/00004728-200603000-00003

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  4 in total

1.  Whole-body computed tomography for multiple traumas using a triphasic injection protocol.

Authors:  Christos Loupatatzis; Sebastian Schindera; Jan Gralla; Hanno Hoppe; Jan Bittner; Ralph Schröder; Sudesh Srivastav; Harald Marcel Bonel
Journal:  Eur Radiol       Date:  2008-02-13       Impact factor: 5.315

2.  Diagnostic accuracy of non-contrast abdominopelvic computed tomography scans in follow-up of breast cancer patients.

Authors:  Sang Yu Nam; Su Joa Ahn; Young Rock Jang; Yong Soon Chun; Heung Kyu Park; Seung Joon Choi; Hye Young Choi; Jeong Ho Kim
Journal:  Br J Radiol       Date:  2020-12-11       Impact factor: 3.039

3.  Optimising the scan delay for arterial phase imaging of the liver using the bolus tracking technique.

Authors:  Rs Chan; G Kumar; Bjj Abdullah; Kh Ng; A Vijayananthan; H Mohd Nor; Yw Liew
Journal:  Biomed Imaging Interv J       Date:  2011-04-01

4.  Is Non-Contrast CT Adequate for the Evaluation of Hepatic Metastasis in Patients Who Cannot Receive Iodinated Contrast Media?

Authors:  Han Bum Jee; Min Jung Park; Hye Sun Lee; Mi-Suk Park; Myeong-Jin Kim; Yong Eun Chung
Journal:  PLoS One       Date:  2015-07-28       Impact factor: 3.240

  4 in total