Literature DB >> 16627456

The RIONI study rationale and design: validation of the first stored electrograms transmitted via home monitoring in patients with implantable defibrillators.

C Perings1, G Klein, E Toft, C Moro, D Klug, D Böcker, H J Trappe, T Korte.   

Abstract

Appropriate and inappropriate therapies of implantable cardioverter defibrillators (ICDs) have a major impact on morbidity and quality of life in ICD recipients. The recently introduced home monitoring of ICD devices is a promising new technique which remotely offers information about the status of the system. Stored intracardiac electrograms (IEGMs), which are essential for correct classification of appropriate and inappropriate ICD discharges, have until now not been available with ICD home monitoring on a day-by-day basis because of limitations of transferable data. We demonstrate the first compressed IEGMs daily transferable via home monitoring (IEGM-online). Validation of these electrograms will be performed in the Reliability of IEGM-Online Interpretation (RIONI) study. A total of 210 episodes of stored IEGMs will be collected by at least 12 European centres. The primary endpoint of this study is to investigate whether the IEGM-online based evaluation of the appropriateness of the ICDs therapeutic decision following episode detection is equivalent to the evaluation based on the complete ICD episode Holter extracted from the IEGM stored. The evaluation is independently done by an expert board of three experienced ICD investigators. The equivalence of the two methods is accepted if the evaluations yield a different conclusion for <10% of all evaluated IEGMs. The conclusion of the study is expected at the beginning of 2007. If RIONI successfully validates IEGMs transmitted via home monitoring, a strong basis for the use of this promising technique will be established.

Entities:  

Mesh:

Year:  2006        PMID: 16627456     DOI: 10.1093/europace/eul009

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  4 in total

Review 1.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.

Authors:  Werner Jung; Andreas Rillig; Ralf Birkemeyer; Tomislav Miljak; Udo Meyerfeldt
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

2.  Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory.

Authors:  Laurence Guédon-Moreau; Philippe Chevalier; Christelle Marquié; Claude Kouakam; Didier Klug; Dominique Lacroix; Francois Brigadeau; Salem Kacet
Journal:  Eur Heart J       Date:  2010-06-30       Impact factor: 29.983

3.  Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes.

Authors:  Massimo Santini; Renato P Ricci; Maurizio Lunati; Maurizio Landolina; Giovanni B Perego; Maurizio Marzegalli; Milena Schirru; Chiara Belvito; Roberto Brambilla; Giuseppe Guenzati; Serena Gilardi; Sergio Valsecchi
Journal:  J Interv Card Electrophysiol       Date:  2008-10-31       Impact factor: 1.900

4.  Remote monitoring of implantable cardioverter defibrillator.

Authors:  Dwight W Reynolds; N Jayaprasad; Johnson Francis
Journal:  Indian Pacing Electrophysiol J       Date:  2006-10-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.