Literature DB >> 16627146

The influence of ambient theater temperature on cement setting time.

Andrew J Langdown1, Nicholas Tsai, Jason Auld, William R Walsh, Peter Walker, Warwick J M Bruce.   

Abstract

We have prospectively recorded ambient operating theater temperature from 186 total knee arthroplasties and the time taken for the cement to set at implantation. The majority of cases used Antibiotic Simplex cement (n = 131), and the rest, Simplex with tobramycin (n = 55). Set time was defined as when a no. 15 scalpel could not indent the cement surface at either the femoral or tibial interface. There was a reasonable negative correlation between temperature and setting time (Antibiotic Simplex: Pearson correlation coefficient, R = -0.674; Simplex with tobramycin: R = -0.655). There was also a considerable variation of setting time at any given theater temperature. There is an inverse relationship between ambient theater temperature and the setting time for Simplex cement, and surgeons should be aware that the setting time can vary considerably. Their operative protocol should take this into account.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16627146     DOI: 10.1016/j.arth.2005.03.032

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Not all approved antibiotic-loaded PMMA bone cement brands are the same: ranking using the utility materials selection concept.

Authors:  Gladius Lewis
Journal:  J Mater Sci Mater Med       Date:  2015-01-17       Impact factor: 3.896

2.  Development of a biodegradable bone cement for craniofacial applications.

Authors:  Allan M Henslee; Dong-Ho Gwak; Antonios G Mikos; F Kurtis Kasper
Journal:  J Biomed Mater Res A       Date:  2012-04-12       Impact factor: 4.396

3.  Effect of shape on bone cement polymerization time in knee joint replacement surgery.

Authors:  Jung-Ro Yoon; Young-Rok Ko; Young-Soo Shin
Journal:  Medicine (Baltimore)       Date:  2018-04       Impact factor: 1.889

4.  Traditions and myths in hip and knee arthroplasty.

Authors:  Henrik Husted; Kirill Gromov; Henrik Malchau; Andrew Freiberg; Peter Gebuhr; Anders Troelsen
Journal:  Acta Orthop       Date:  2014-10-06       Impact factor: 3.717

5.  Effect of storage temperature and equilibration time on polymethyl methacrylate (PMMA) bone cement polymerization in joint replacement surgery.

Authors:  Bryan T H Koh; J H Tan; Amit Kumarsing Ramruttun; Wilson Wang
Journal:  J Orthop Surg Res       Date:  2015-11-17       Impact factor: 2.359

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.