Literature DB >> 16624545

Registration of T-2 mycotoxin with total internal reflection ellipsometry and QCM impedance methods.

A V Nabok1, A Tsargorodskaya, A Holloway, N F Starodub, O Gojster.   

Abstract

A sensitive optical method of total internal reflection ellipsometry (TIRE) in conjunction with immune assay approach was exploited for the registration of T-2 mycotoxin in a wide range of concentrations from 100 microg/ml down to 0.15 ng/ml. Association constants of 1.4x10(6) and 1.9x10(7)mol(-1)s for poly- and monoclonal T-2 antibodies, respectively, were evaluated from TIRE kinetic measurements. According to TIRE data fitting, binding of T-2 molecules to antibodies (at saturation) has resulted in the increase in adsorbed layer thickness of 4-5 nm. The QCM impedance measurements data showed anomalously large mass increase and film softening, most likely, due to the binding of large T-2 aggregates to antibodies.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16624545     DOI: 10.1016/j.bios.2006.03.010

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

1.  Study of receptor-chaperone interactions using the optical technique of spectroscopic ellipsometry.

Authors:  Verena Kriechbaumer; Anna Tsargorodskaya; Mohd K Mustafa; Tatiana Vinogradova; Joanne Lacey; David P Smith; Benjamin M Abell; Alexei Nabok
Journal:  Biophys J       Date:  2011-07-20       Impact factor: 4.033

2.  Ellipsometric-based novel DNA biosensor for label-free, real-time detection of Bordetella parapertussis.

Authors:  S Rafique; M Idrees; H Bokhari; A S Bhatti
Journal:  J Biol Phys       Date:  2019-08-02       Impact factor: 1.365

Review 3.  Small molecule immunosensing using surface plasmon resonance.

Authors:  John Mitchell
Journal:  Sensors (Basel)       Date:  2010-08-04       Impact factor: 3.576

Review 4.  Advances in Biosensors, Chemosensors and Assays for the Determination of Fusarium Mycotoxins.

Authors:  Xialu Lin; Xiong Guo
Journal:  Toxins (Basel)       Date:  2016-05-24       Impact factor: 4.546

5.  Optimization of Apta-Sensing Platform for Detection of Prostate Cancer Marker PCA3.

Authors:  Sarra Takita; Alexei Nabok; Anna Lishchuk; David Smith
Journal:  Int J Mol Sci       Date:  2021-11-24       Impact factor: 5.923

6.  Mycotoxin detection plays "cops and robbers": cyclodextrin chemosensors as specialized police?

Authors:  Pietro Cozzini; Gianluigi Ingletto; Ratna Singh; Chiara Dall'Asta
Journal:  Int J Mol Sci       Date:  2008-12-05       Impact factor: 6.208

7.  Label-Free Optical Detection of Mycotoxins Using Specific Aptamers Immobilized on Gold Nanostructures.

Authors:  Ali Ghanim Al-Rubaye; Alexei Nabok; Gaelle Catanante; Jean-Louis Marty; Eszter Takács; András Székács
Journal:  Toxins (Basel)       Date:  2018-07-16       Impact factor: 4.546

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.