Literature DB >> 16620529

Determination of benzodiazepines in human urine using solid-phase extraction and high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

S Hegstad1, E L Øiestad, U Johansen, A S Christophersen.   

Abstract

A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for the determination of benzodiazepines, on the market in Norway, and/or their metabolites in human urine. The following compounds were included: 7-aminonitrazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, alprazolam, alpha-hydroxyalprazolam, oxazepam, 3-OH-diazepam, and n-desmethyldiazepam. The method includes hydrolysis of urine samples (0.5 mL) with beta-glucuronidase at 60 degrees C for 2 h before solid-phase extraction with a polymer-based mixed-mode column. The analytes were quantified in multiple reaction monitoring mode using two transitions. Deuterated analogues were used as internal standards for all analytes except 7-aminonitrazepam and alpha-hydroxyalprazolam, which were quantified using 7-aminoclonazepam-d(4) and alprazolam-d(5), respectively. The concentration range was 0.1-8.0 microM for 7-aminonitrazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, alprazolam, and alpha-hydroxyalprazolam and 0.5-40 microM for the other compounds. The average recovery for the different analytes ranged from 56% to 83%. The between-day precision of the method was in the range of 3-12%. The limits of quantification were found to be between 0.002 and 0.01 microM for the different compounds. Comparison with other analytical methods was performed for method validation, using approximately 500 samples provided by the routine laboratory at the Norwegian Institute of Public Health. The LC-MS-MS method has proven to be robust and specific for the determination of benzodiazepines in urine. It has been routinely used for approximately 1800 samples in the past 7 months.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16620529     DOI: 10.1093/jat/30.1.31

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  4 in total

Review 1.  Modern instrumental methods in forensic toxicology.

Authors:  Michael L Smith; Shawn P Vorce; Justin M Holler; Eric Shimomura; Joe Magluilo; Aaron J Jacobs; Marilyn A Huestis
Journal:  J Anal Toxicol       Date:  2007-06       Impact factor: 3.367

2.  Polyacrylonitrile/MIL-53(Fe) electrospun nanofiber for pipette-tip micro solid phase extraction of nitrazepam and oxazepam followed by HPLC analysis.

Authors:  Shima Amini; Homeira Ebrahimzadeh; Shahram Seidi; Niloofar Jalilian
Journal:  Mikrochim Acta       Date:  2020-01-31       Impact factor: 5.833

3.  A silica fiber coated with a ZnO-graphene oxide nanocomposite with high specific surface for use in solid phase microextraction of the antiepileptic drugs diazepam and oxazepam.

Authors:  Reza Alizadeh; Maryam Salami; Shahram Seidi
Journal:  Mikrochim Acta       Date:  2018-06-02       Impact factor: 5.833

4.  Rapid Analysis of Cocaine in Saliva by Surface-Enhanced Raman Spectroscopy.

Authors:  Kathryn Dana; Chetan Shende; Hermes Huang; Stuart Farquharson
Journal:  J Anal Bioanal Tech       Date:  2015
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.