Literature DB >> 16617196

Removal resistance of glass-fiber and metallic cast posts with different lengths.

Neilor Mateus Antunes Braga1, Silvana Maria Paulino, Edson Alfredo, Manoel Damião Sousa-Neto, Luiz Pascoal Vansan.   

Abstract

This study evaluated the strength required to remove glass-fiber and metallic cast posts with different lengths. Sixty endodontically treated canines were included and their roots were embedded in acrylic resin after discarding the crowns. Samples were randomly assigned to 3 groups according to the post length (n = 20): I- 6 mm, II - 8 mm and III- 10 mm. Each group was divided into 2 subgroups based on the post material (n = 10): A- glass fiber or B- metallic cast. Post-space was prepared with Fibrekor Post Kit attached to a parallelometer. In subgroup A, prefabricated glass fiber posts from Fibrekor Post Kit were utilized. In metallic post group (subgroup B), an impression of post space was obtained, followed by casting. All posts were luted with Panavia F cement. A universal testing machine determined the force required to dislodge each post. ANOVA analysis indicated significant differences (P < 0.01) among post length. Tukey test showed that posts with 10 mm-length showed higher resistance on removal than posts with 6 mm-length. Posts with 8 mm-length did not exhibit difference when compared to 6 and 10 mm posts. No significant differences (P > 0.05) were observed between the tested post materials. It was concluded that the type of post did not influence the removal resistance and that posts with 10 mm-length required greater force to be dislodged.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16617196     DOI: 10.2334/josnusd.48.15

Source DB:  PubMed          Journal:  J Oral Sci        ISSN: 1343-4934            Impact factor:   1.556


  5 in total

1.  Evaluation of different post lengths' effect on fracture resistance of a glass fiber post system.

Authors:  Necdet Adanir; Sema Belli
Journal:  Eur J Dent       Date:  2008-01

2.  Influence of the length of remaining root canal filling and post space preparation on the coronal leakage of Enterococcus faecalis.

Authors:  Alexandra Conca Alves Mozini; Luis P Vansan; Manoel D Sousa Neto; Rosimeire Pietro
Journal:  Braz J Microbiol       Date:  2009-03-01       Impact factor: 2.476

3.  Retentive strength of different intracanal posts in restorations of anterior primary teeth: an in vitro study.

Authors:  Mahtab Memarpour; Fereshteh Shafiei; Maryam Abbaszadeh
Journal:  Restor Dent Endod       Date:  2013-11-12

4.  In vitro fracture resistance of zirconia, glass-fiber, and cast metal posts with different lengths.

Authors:  Ashutosh B Palepwad; Rahul Shyamrao Kulkarni
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

5.  Does Multi-Fiber-Reinforced Composite-Post Influence the Filling Ability and the Bond Strength in Root Canal?

Authors:  Naji Kharouf; Salvatore Sauro; Hamdi Jmal; Ammar Eid; Mohamed Karrout; Nadia Bahlouli; Youssef Haikel; Davide Mancino
Journal:  Bioengineering (Basel)       Date:  2021-11-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.