Literature DB >> 16616485

Amperometric glucose biosensor based on polymerized ionic liquid microparticles.

M Sánchez-Paniagua López1, D Mecerreyes, E López-Cabarcos, B López-Ruiz.   

Abstract

A glucose amperometric biosensor based on the immobilization of glucose oxidase (GOx) in microparticles prepared by polymerization of the ionic liquid 1-vinyl-3-ethyl-imidazolium bromide (ViEtIm+ Br-) using the concentrated emulsion polymerization method has been developed. The polymerization of the emulsion dispersed phase, in which the enzyme was dissolved together with the ionic liquid monomer, provides poly(ViEtIm+ Br-) microparticles with entrapped GOx. An anion-exchange reaction was carried out for synthesizing new microparticles of poly(ViEtIm+ (CF3SO2)2N-) and poly(ViEtIm+ BF4-). The enzyme immobilization method was optimized for biosensor applications and the following optimal values were determined: pH 4.0 for the synthesis medium, 1.23 M monomer concentration and 3.2% (w/w) cross-linking content. The performance of the biosensor as a function of some analytical parameters such as pH and temperature of the measuring medium, and enzymatic load of the microparticles was also investigated. The effect of the substances which are present in serum samples such as uric and ascorbic acid was eliminated by using a thin Nafion layer covering the electrode surface. The biosensor thus prepared can be employed in aqueous and in non-aqueous media with satisfactory results for glucose determination in human serum samples. The useful lifetime of this biosensor was 150 days.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16616485     DOI: 10.1016/j.bios.2006.02.019

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Modulation of fibroblast inflammatory response by surface modification of a perfluorinated ionomer.

Authors:  Thelma I Valdes; Winston Ciridon; Buddy D Ratner; James D Bryers
Journal:  Biointerphases       Date:  2011-06       Impact factor: 2.456

Review 2.  Recent developments in biocatalysis in multiphasic ionic liquid reaction systems.

Authors:  Lars-Erik Meyer; Jan von Langermann; Udo Kragl
Journal:  Biophys Rev       Date:  2018-04-27

3.  Highly stable acetylcholinesterase electrochemical biosensor based on polymerized ionic liquids microgel for pesticides detection.

Authors:  Yu Wan; Huiting Wang; Ling Zhang; Yaxian Chen; Shun Li; Jie Zhou; Qian Zhang; Lixin Xia
Journal:  Mikrochim Acta       Date:  2022-07-29       Impact factor: 6.408

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.