Literature DB >> 16616037

Frequency and causes of implantable cardioverter-defibrillator therapies: is device therapy proarrhythmic?

Joseph J Germano1, Matthew Reynolds, Vidal Essebag, Mark E Josephson.   

Abstract

Implantable cardioverter-defibrillator (ICD) shocks diminish patients' quality of life, increase health care resource utilization, and may lead to other adverse sequelae. Better understanding of the factors that lead to ICD therapies, and better strategies to avoid unnecessary therapies, are needed to optimize patient outcomes. Data from major randomized clinical trials involving the use of ICDs and cardiac resynchronization therapy-defibrillator devices were reviewed to determine control group mortality rates, control group sudden death rates, and the frequency of appropriate and inappropriate ICD therapies. In all studies that classified deaths, appropriate ICD therapies outnumbered control group sudden cardiac deaths by a factor of 2 to 3. Some of these episodes can be explained by device programming, by the treatment of potentially unsustained tachycardias, and by errors of episode classification. Another underexplored possibility is that device therapy is proarrhythmic. Reasons for frequent therapies and methods to prevent them are discussed, as well as the notion of device proarrhythmia and the potentially detrimental effects of ICD shocks. These issues clearly affect the overall benefit of device therapy and have important implications for patient management and health care delivery.

Entities:  

Mesh:

Year:  2006        PMID: 16616037     DOI: 10.1016/j.amjcard.2005.11.048

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  58 in total

1.  Clinical utility of microvolt T-wave alternans testing in identifying patients at high or low risk of sudden cardiac death.

Authors:  Faisal M Merchant; Takanori Ikeda; Roberto F E Pedretti; Jorge A Salerno-Uriarte; Theodore Chow; Paul S Chan; Cheryl Bartone; Stefan H Hohnloser; Richard J Cohen; Antonis A Armoundas
Journal:  Heart Rhythm       Date:  2012-03-08       Impact factor: 6.343

Review 2.  Role of substrate and triggers in the genesis of cardiac alternans, from the myocyte to the whole heart: implications for therapy.

Authors:  Faisal M Merchant; Antonis A Armoundas
Journal:  Circulation       Date:  2012-01-24       Impact factor: 29.690

Review 3.  Strategic choices to reduce implantable cardioverter-defibrillator-related morbidity.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2010-04-20       Impact factor: 32.419

4.  The Entirely Subcutaneous Defibrillator - A New Generation and Future Expectations.

Authors:  Hussam Ali; Pierpaolo Lupo; Riccardo Cappato
Journal:  Arrhythm Electrophysiol Rev       Date:  2015-08

Review 5.  Predictive value of microvolt T-wave alternans for cardiac death or ventricular tachyarrhythmic events in ischemic and nonischemic cardiomyopathy patients: a meta-analysis.

Authors:  Leonardo Calò; Tiziana De Santo; Francesca Nuccio; Luigi Sciarra; Lucia De Luca; Lorenza Mangoni di S Stefano; Enrico Piroli; Lorenzo Zuccaro; Marco Rebecchi; Ermenegildo de Ruvo; Ernesto Lioy
Journal:  Ann Noninvasive Electrocardiol       Date:  2011-10       Impact factor: 1.468

Review 6.  Implications of arrhythmias and prevention of sudden death in hypertrophic cardiomyopathy.

Authors:  A Selcuk Adabag; Barry J Maron
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-04       Impact factor: 1.468

7.  [Annual Report 2011 of the German pacemaker and defibrillator register: Section pacemakers and AQUA-Institute for Applied Quality Improvement and Research in Health Care].

Authors:  A Markewitz
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-12

Review 8.  [Limitations and possibilities of noninvasive risk stratification for sudden cardiac death].

Authors:  Tobias Tönnis; Karl-Heinz Kuck
Journal:  Herz       Date:  2009-11       Impact factor: 1.443

Review 9.  Current status of implantable cardioverter-defibrillator therapy in heart failure.

Authors:  Ilknur Can; Venkatakrishna N Tholakanahalli
Journal:  Curr Heart Fail Rep       Date:  2009-09

10.  Incessant ventricular tachycardia, refractory to catheter ablation, in an ICD patient terminated by ICD lead extraction: a case report.

Authors:  Corinna Lenz; Thomas Dietze; Michael Möller; Wolfgang Schöbel; Jens Wicke; Hans-Jörg Kellner; Rainer Gradaus; Jörg Neuzner
Journal:  Clin Res Cardiol       Date:  2009-08-28       Impact factor: 5.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.