Identification and quantification of homologous series of compound in complex mixtures: autocovariance study of GC/MS chromatograms.

Maria Chiara Pietrogrande1, Maria Grazia Zampolli, Francesco Dondi.   

Abstract

The paper describes a method for determining homologous classes of compounds in a multicomponent complex chromatogram obtained under programming elution conditions. The method is based on the computation of the autocovariance function of the experimental chromatogram (EACVF). The EACVF plot, if properly interpreted, can be regarded as a "class chromatogram" i.e., a virtual chromatogram formed by peaks whose positions and heights allow identification and quantification of the different homologous series, even if they are embedded in a random complex chromatogram. Theoretical models were developed to describe complex chromatograms displaying random retention pattern, ordered sequences or a combination of them. On the basis of theoretical autocovariance function, the properties of the chromatogram can be experimentally evaluated, under well-defined conditions: in particular, the two components of the chromatogram, ordered and random, can be identified. Moreover, the total number of single components (SCs) and the separated number of the SCs belonging to the random and ordered components can be determined, when the two components display the same concentration. If the mixture contains several homologous series with common frequency and different phase values, the number and identity of the different homologous series as well as the number of SCs belonging to each of them can be evaluated. Moreover, the power of the EACVF method can be magnified by applying it to the single ion monitoring (SIM) signals to selectively detect specific compound classes in order to identify the different homologous series. By this way, a full "decoding" of the complex multicomponent chromatogram is achieved. The method was validated on synthetic mixtures containing known amount of SCs belonging to homologous series of hydrocarbon, alcohols, ketones, and aromatic compounds in addition to other not structurally related SCs. The method was applied to both the total ion monitoring (TIC) and the SIM signals, to describe step by step the essence of the procedure. Moreover, the systematic use of both SIM and TIC can simplify the decoding procedure of complex chromatograms by singling out only specific compound classes or by confirming the identification of the different homologous series. The method was further applied to a sample containing unknown number of compounds and homologous series (a petroleum benzin, bp 140-160 degrees C): the results obtained were meaningful in terms of both the identified number of components and identified homologous series.

Entities:  

Year:  2006        PMID: 16615767     DOI: 10.1021/ac051491e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Nontargeted homologue series extraction from hyphenated high resolution mass spectrometry data.

Authors:  Martin Loos; Heinz Singer
Journal:  J Cheminform       Date:  2017-02-23       Impact factor: 5.514

2.  Current literature in mass spectrometry.

Authors: 
Journal:  J Mass Spectrom       Date:  2007-01       Impact factor: 1.982

  2 in total