Literature DB >> 16609353

Left ventricular ejection fraction and volumes on rest gated 201Tl perfusion SPECT: comparison with two-dimensional echocardiography.

Chetan D Patel1, Murali R Nadig, Sumodh Kurien, Sukanta Barai, Rajeev Narang, Arun Malhotra.   

Abstract

BACKGROUND: Rest gated 201Tl images are considered to be of poor count statistics due to lower energy and low photon flux of 201Tl in addition to increased attenuation and low dose that can be administered. We compared the left ventricular ejection fraction (LVEF), end diastolic (EDV) and end systolic volume (ESV) obtained on 4 h gated rest 201Tl myocardial perfusion single photon emission computed tomography (SPECT) with those obtained by two-dimensional echocardiography (2-D ECHO) in patients with known or suspected coronary artery disease (CAD).
METHODS: Eighty-two consecutive patients who underwent gated 201Tl stress-rest myocardial perfusion SPECT and 2-D ECHO were studied. The gated thallium images were processed with Siemens e-soft autocardiac processor and LVEF, EDV and ESV were evaluated using Emory Cardiac Toolbox. The same parameters were also assessed on the 2-D ECHO using the modified Simpson method for comparison.
RESULTS: Out of 82 rest gated images, one study was excluded because of poor count statistics. In 81 (99%) patients there was good linear correlation with 2-D ECHO values and rest gated 201Tl SPECT images for EDV, ESV and LVEF. Pearson's correlation co-efficient (r value) for EDV, ESV and LVEF between the two methods was 0.78, 0.79 and 0.88, respectively. A Bland-Altman plot showed close agreement with LVEF but not for EDV and ESV.
CONCLUSION: These results suggest that the 4 h rest gated 201Tl study gives a reliable value for the LVEF compared to 2-D ECHO and can be used in routine clinical practice.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16609353     DOI: 10.1097/00006231-200605000-00003

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  5 in total

1.  Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters.

Authors:  Satoshi Kurisu; Yoji Sumimoto; Hiroki Ikenaga; Noriaki Watanabe; Ken Ishibashi; Yoshihiro Dohi; Yukihiro Fukuda; Yasuki Kihara
Journal:  Heart Vessels       Date:  2016-12-17       Impact factor: 2.037

2.  Effects of hemoglobin level on myocardial washout rate of thallium-201 in patients with normal myocardial perfusion assessed by single-photon emission computed tomography.

Authors:  Satoshi Kurisu; Yoji Sumimoto; Hiroki Ikenaga; Noriaki Watanabe; Ken Ishibashi; Yoshihiro Dohi; Yukihiro Fukuda; Yasuki Kihara
Journal:  Heart Vessels       Date:  2017-04-05       Impact factor: 2.037

3.  Comparison and co-relation of invasive and noninvasive methods of ejection fraction measurement.

Authors:  Darshan Godkar; Kalyan Bachu; Bijal Dave; Robert Megna; Selva Niranjan; Ashok Khanna
Journal:  J Natl Med Assoc       Date:  2007-11       Impact factor: 1.798

4.  Thallium-201 gated single-photon emission tomography for assessing left ventricular volumes and function in patients with aortic valve stenosis: Comparison with echocardiography as the reference standard.

Authors:  Satoshi Kurisu; Toshitaka Iwasaki; Hiroki Ikenaga; Noriaki Watanabe; Tadanao Higaki; Takashi Shimonaga; Ken Ishibashi; Naoya Mitsuba; Yoshihiro Dohi; Yasuki Kihara
Journal:  Int J Cardiol Heart Vasc       Date:  2014-10-08

5.  Prevalence of left ventricular dysfunction in rheumatoid arthritis.

Authors:  A S Renjith; Vishal Marwaha; N Aggarwal; Varghese Koshy; V K Singal; K V S Hari Kumar
Journal:  J Family Med Prim Care       Date:  2017 Jul-Sep
  5 in total