Literature DB >> 16609218

Fixed-exit monochromator for computed tomography with synchrotron radiation at energies 18-90 keV.

P Suortti1, S Fiedler, A Bravin, T Brochard, M Mattenet, M Renier, P Spanne, W Thomlinson, A M Charvet, H Elleaume, C Schulze-Briese, A C Thompson.   

Abstract

A fixed-exit monochromator has been constructed for computed tomography (CT) studies at the Medical Beamline of the European Synchrotron Radiation Facility. A non-dispersive pair of bent Laue-type crystals is used, and the first crystal is water-cooled. The monochromator operates at energies from 18 to 90 keV, and the maximum width of the beam is 150 mm. The performance of the monochromator is studied with respect to the beam intensity and energy distributions, and a close agreement is found between the calculated and experimental results. The intensity is between 10(9) and 10(10) photons s(-1) mm(-2) under typical operating conditions. The harmonic content of a 25 keV beam is about 30% at the minimum wiggler gap of 25 mm (field 1.57 T) and decreases by an order of magnitude when the gap is increased to 60 mm (field 0.62 T). The experimental set-up for CT studies includes dose monitors, goniometers and translation stages for positioning and scanning the object, and a 432-element linear-array Ge detector. Examples from phantom studies and in vivo animal experiments are shown to illustrate the spatial resolution and contrast of the reconstructed images.

Year:  2000        PMID: 16609218     DOI: 10.1107/S0909049500008384

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  4 in total

1.  Regional Behavior of Airspaces During Positive Pressure Reduction Assessed by Synchrotron Radiation Computed Tomography.

Authors:  Gaetano Scaramuzzo; Ludovic Broche; Mariangela Pellegrini; Liisa Porra; Savino Derosa; Angela Principia Tannoia; Andrea Marzullo; Joao Batista Borges; Sam Bayat; Alberto Bravin; Anders Larsson; Gaetano Perchiazzi
Journal:  Front Physiol       Date:  2019-06-07       Impact factor: 4.566

2.  Imaging atelectrauma in Ventilator-Induced Lung Injury using 4D X-ray microscopy.

Authors:  Luca Fardin; Ludovic Broche; Goran Lovric; Alberto Mittone; Olivier Stephanov; Anders Larsson; Alberto Bravin; Sam Bayat
Journal:  Sci Rep       Date:  2021-02-19       Impact factor: 4.379

3.  Synchrotron radiation-based experimental determination of the optimal energy for cell radiotoxicity enhancement following photoelectric effect on stable iodinated compounds.

Authors:  S Corde; A Joubert; J F Adam; A M Charvet; J F Le Bas; F Estève; H Elleaume; J Balosso
Journal:  Br J Cancer       Date:  2004-08-02       Impact factor: 7.640

4.  Lung tissue biomechanics imaged with synchrotron phase contrast microtomography in live rats.

Authors:  Jose-Luis Cercos-Pita; Luca Fardin; Hugo Leclerc; Bertrand Maury; Gaetano Perchiazzi; Alberto Bravin; Sam Bayat
Journal:  Sci Rep       Date:  2022-03-23       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.