Literature DB >> 16609026

Performance of immuno-positron emission tomography with zirconium-89-labeled chimeric monoclonal antibody U36 in the detection of lymph node metastases in head and neck cancer patients.

Pontus K E Börjesson1, Yvonne W S Jauw, Ronald Boellaard, Remco de Bree, Emile F I Comans, Jan C Roos, Jonas A Castelijns, Maria J W D Vosjan, J Alain Kummer, C René Leemans, Adriaan A Lammertsma, Guus A M S van Dongen.   

Abstract

PURPOSE: Immuno-positron emission tomography (PET), the combination of PET with monoclonal antibodies (mAb), is an attractive option to improve tumor detection and to guide mAb-based therapy. The long-lived positron emitter zirconium-89 ((89)Zr) has ideal physical characteristics for immuno-PET with intact mAbs but has never been used in a clinical setting. In the present feasibility study, we aimed to evaluate the diagnostic imaging performance of immuno-PET with (89)Zr-labeled-chimeric mAb (cmAb) U36 in patients with squamous cell carcinoma of the head and neck (HNSCC), who were at high risk of having neck lymph node metastases. EXPERIMENTAL
DESIGN: Twenty HNSCC patients, scheduled to undergo neck dissection with or without resection of the primary tumor, received 75 MBq (89)Zr coupled to the anti-CD44v6 cmAb U36 (10 mg). All patients were examined by computed tomography (CT) and/or magnetic resonance imaging (MRI) and immuno-PET before surgery. Six patients also underwent PET with (18)F-fluoro-2-deoxy-d-glucose. Immuno-PET scans were acquired up to 144 hours after injection. Diagnostic findings were recorded per neck side (left or right) as well as per lymph node level (six levels per side), and compared with histopathologic outcome. For this purpose, the CT/MRI scores were combined and the best of both scores was used for analysis.
RESULTS: Immuno-PET detected all primary tumors (n = 17) as well as lymph node metastases in 18 of 25 positive levels (sensitivity 72%) and in 11 of 15 positive sides (sensitivity 73%). Interpretation of immuno-PET was correct in 112 of 121 operated levels (accuracy 93%) and in 19 of 25 operated sides (accuracy 76%). For CT/MRI, sensitivities of 60% and 73% and accuracies of 90% and 80% were found per level and side, respectively. In the six patients with seven tumor-involved neck levels and sides, immuno-PET and (18)F-fluoro-2-deoxy-d-glucose PET gave comparable diagnostic results.
CONCLUSION: In this study, immuno-PET with (89)Zr-cmAb U36 performed at least as good as CT/MRI for detection of HNSCC lymph node metastases.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16609026     DOI: 10.1158/1078-0432.CCR-05-2137

Source DB:  PubMed          Journal:  Clin Cancer Res        ISSN: 1078-0432            Impact factor:   12.531


  80 in total

Review 1.  PET tracers based on Zirconium-89.

Authors:  Yin Zhang; Hao Hong; Weibo Cai
Journal:  Curr Radiopharm       Date:  2011-04

2.  Development of a novel long-lived immunoPET tracer for monitoring lymphoma therapy in a humanized transgenic mouse model.

Authors:  Arutselvan Natarajan; Frezghi Habte; Sanjiv S Gambhir
Journal:  Bioconjug Chem       Date:  2012-06-11       Impact factor: 4.774

Review 3.  Coordinating radiometals of copper, gallium, indium, yttrium, and zirconium for PET and SPECT imaging of disease.

Authors:  Thaddeus J Wadas; Edward H Wong; Gary R Weisman; Carolyn J Anderson
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

Review 4.  Development of radioimmunotherapeutic and diagnostic antibodies: an inside-out view.

Authors:  C Andrew Boswell; Martin W Brechbiel
Journal:  Nucl Med Biol       Date:  2007-06-08       Impact factor: 2.408

5.  Metallic radionuclides in the development of diagnostic and therapeutic radiopharmaceuticals.

Authors:  Sibaprasad Bhattacharyya; Manish Dixit
Journal:  Dalton Trans       Date:  2011-05-03       Impact factor: 4.390

Review 6.  Progress of Coordination and Utilization of Zirconium-89 for Positron Emission Tomography (PET) Studies.

Authors:  Minh Thanh La; Van Hieu Tran; Hee-Kwon Kim
Journal:  Nucl Med Mol Imaging       Date:  2019-01-29

7.  A versatile bifunctional chelate for radiolabeling humanized anti-CEA antibody with In-111 and Cu-64 at either thiol or amino groups: PET imaging of CEA-positive tumors with whole antibodies.

Authors:  Lin Li; James Bading; Paul J Yazaki; Amitkumar H Ahuja; Desiree Crow; David Colcher; Lawrence E Williams; Jeffrey Y C Wong; Andrew Raubitschek; John E Shively
Journal:  Bioconjug Chem       Date:  2007-11-08       Impact factor: 4.774

8.  Inert coupling of IRDye800CW and zirconium-89 to monoclonal antibodies for single- or dual-mode fluorescence and PET imaging.

Authors:  Ruth Cohen; Danielle J Vugts; Marijke Stigter-van Walsum; Gerard W M Visser; Guus A M S van Dongen
Journal:  Nat Protoc       Date:  2013-04-25       Impact factor: 13.491

9.  Measuring the pharmacodynamic effects of a novel Hsp90 inhibitor on HER2/neu expression in mice using Zr-DFO-trastuzumab.

Authors:  Jason P Holland; Eloisi Caldas-Lopes; Vadim Divilov; Valerie A Longo; Tony Taldone; Danuta Zatorska; Gabriela Chiosis; Jason S Lewis
Journal:  PLoS One       Date:  2010-01-25       Impact factor: 3.240

10.  p-Isothiocyanatobenzyl-desferrioxamine: a new bifunctional chelate for facile radiolabeling of monoclonal antibodies with zirconium-89 for immuno-PET imaging.

Authors:  Lars R Perk; Maria J W D Vosjan; Gerard W M Visser; Marianne Budde; Paul Jurek; Garry E Kiefer; Guus A M S van Dongen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-18       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.