Literature DB >> 16608501

Liver iron content assessment by routine and simple magnetic resonance imaging procedure in highly transfused patients.

Christian Rose1, Philippe Vandevenne, Emmanuelle Bourgeois, Nathalie Cambier, Olivier Ernst.   

Abstract

BACKGROUND: Liver iron content (LIC) assessment by magnetic resonance imaging (MRI) is validated but not standardized. In a single center, we tried to assess the accuracy of a specific, simple MRI procedure adapted to high LIC from a well-established simple and routine procedure known to quantify LIC.
METHODS: In 27 cases of monthly transfused patients, we compared biochemical values of LIC assessed on liver biopsy specimens and results obtained by two signal intensity ratio of gradient echo imaging (R2*) MRI protocols. The first was Gandon's routine procedure previously validated in liver disease and the second, our own method, was an addition of a gradient echo sequence specifically adapted to high LIC encountered in hematology practice.
RESULTS: Twenty-seven liver biopsies were performed in 18 adult patients (myelodysplastic syndrome = 5, beta-thalassemia = 13). LIC by biopsy ranged from 1.4 to 54 mg/g liver dry weight (mg/g dw) (median 9.4 mg/g dw). Correlation between LIC by biopsy and by MRI with Gandon's procedure was good (R = 0.80) in patients with LIC falling within the range reported by Gandon. By contrast, a weak correlation was demonstrated (R = 0.52) in patients with high LIC (above 11.2 mg/g dw). With our sequences, the correlation was good both in the entire group of patients (R = 0.83) and in patients with LIC above 11.2 mg/g dw (R = 0.85).
CONCLUSION: Our results suggest that the addition of a specific shorter-gradient echo sequence to a very simple, fast technique produces an accurate estimation of LIC in post-transfusional iron overload.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16608501     DOI: 10.1111/j.0902-4441.2006.t01-1-EJH2571.x

Source DB:  PubMed          Journal:  Eur J Haematol        ISSN: 0902-4441            Impact factor:   2.997


  17 in total

Review 1.  Magnetic resonance imaging quantification of liver iron.

Authors:  Claude B Sirlin; Scott B Reeder
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-08       Impact factor: 2.266

2.  Liver iron concentration quantification by MRI: are recommended protocols accurate enough for clinical practice?

Authors:  Agustin Castiella; Jose M Alústiza; Jose I Emparanza; Eva Ma Zapata; Belen Costero; Maria I Díez
Journal:  Eur Radiol       Date:  2010-08-06       Impact factor: 5.315

Review 3.  Liver iron content determination by magnetic resonance imaging.

Authors:  Konstantinos Tziomalos; Vassilios Perifanis
Journal:  World J Gastroenterol       Date:  2010-04-07       Impact factor: 5.742

4.  Evaluation of liver tissue by ultrasound elastography and clinical parameters in children with multiple blood cell transfusions.

Authors:  Georg W Wurschi; Karim Kentouche; Karl-Heinz Herrmann; Ines Krumbein; Mariana Nold; James F Beck; Jürgen R Reichenbach; Hans-Joachim Mentzel
Journal:  Pediatr Radiol       Date:  2019-03-29

5.  Non-invasive measurement of liver iron concentration using 3-Tesla magnetic resonance imaging: validation against biopsy.

Authors:  Gaspard d'Assignies; Anita Paisant; Edouard Bardou-Jacquet; Anne Boulic; Elise Bannier; Fabrice Lainé; Martine Ropert; Jeff Morcet; Hervé Saint-Jalmes; Yves Gandon
Journal:  Eur Radiol       Date:  2017-11-24       Impact factor: 5.315

6.  Polystyrene microsphere-ferritin conjugates: a robust phantom for correlation of relaxivity and size distribution.

Authors:  Preeti A Sukerkar; Uzma G Rezvi; Keith W Macrenaris; Pinal C Patel; John C Wood; Thomas J Meade
Journal:  Magn Reson Med       Date:  2010-10-28       Impact factor: 4.668

Review 7.  MR imaging assessment and quantification of liver iron.

Authors:  Manuela França; João Gomes Carvalho
Journal:  Abdom Radiol (NY)       Date:  2020-11

8.  Assessment of liver iron overload by 3 T MRI.

Authors:  A Paisant; A Boulic; E Bardou-Jacquet; E Bannier; G d'Assignies; F Lainé; B Turlin; Y Gandon
Journal:  Abdom Radiol (NY)       Date:  2017-06

Review 9.  Quantification of liver iron with MRI: state of the art and remaining challenges.

Authors:  Diego Hernando; Yakir S Levin; Claude B Sirlin; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2014-03-03       Impact factor: 4.813

Review 10.  Estimating tissue iron burden: current status and future prospects.

Authors:  John C Wood
Journal:  Br J Haematol       Date:  2015-03-12       Impact factor: 6.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.