Literature DB >> 16608063

Nonlinear motion correction of respiratory-gated lung SPECT images.

Hidenori Ue1, Hideaki Haneishi, Hideyuki Iwanaga, Kazuyoshi Suga.   

Abstract

We propose a method for correcting the motion of the lungs between different phase images obtained by respiratory-gated single photon emission computed tomography (SPECT). This method is applied to SPECT images that show a preserved activity distribution in the lungs such as 99m-Tc macro aggregated albumin (99m-Tc-MAA) perfusion images and 99m-Tc-Technegas ventilation images. In the proposed method, an objective function, which consists of both the degree of similarity between a reference image and a deformed image, and the smoothness of deformation is defined and optimized using a simulated annealing algorithm. For the degree of similarity term in the objective function, an expansion ratio, defined as the ratio of change in local volume due to deformation, is introduced to preserve the total activity during the motion correction process. This method was applied to data simulated from computer phantoms, data acquired from a physical phantom, and 17 sets of clinical data. In all cases, the motion correction between inspiration and expiration phase images was successfully achieved.

Entities:  

Mesh:

Year:  2006        PMID: 16608063     DOI: 10.1109/TMI.2006.871546

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

Authors:  Yilin Liu; Fang-Fang Yin; DongJoo Rhee; Jing Cai
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Registration and Summation of Respiratory-Gated or Breath-Hold PET Images Based on Deformation Estimation of Lung from CT Image.

Authors:  Hideaki Haneishi; Masayuki Kanai; Yoshitaka Tamai; Atsushi Sakohira; Kazuyoshi Suga
Journal:  Comput Math Methods Med       Date:  2016-12-19       Impact factor: 2.238

3.  Variations Between Dose-Ventilation and Dose-Perfusion Metrics in Radiation Therapy Planning for Lung Cancer.

Authors:  Yujiro Nakajima; Noriyuki Kadoya; Tomoki Kimura; Kazunari Hioki; Keiichi Jingu; Tokihiro Yamamoto
Journal:  Adv Radiat Oncol       Date:  2020-03-20

4.  A deep learning method for translating 3DCT to SPECT ventilation imaging: First comparison with 81m Kr-gas SPECT ventilation imaging.

Authors:  Tomohiro Kajikawa; Noriyuki Kadoya; Yosuke Maehara; Hiroshi Miura; Yoshiyuki Katsuta; Shinsuke Nagasawa; Gen Suzuki; Hideya Yamazaki; Nagara Tamaki; Kei Yamada
Journal:  Med Phys       Date:  2022-05-17       Impact factor: 4.506

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.