Multivariate analysis for operative mortality in obstructive prosthetic valve dysfunction due to pannus and thrombus formation.

Mehmet Erdem Toker1, Ercan Eren, Mehmet Balkanay, Kaan Kirali, Mehmet Yanartaş, Ahmet Calişkan, Mustafa Güler, Cevat Yakut.   

Abstract

The objective of the present study was to investigate the risk factors for early hospital mortality in reoperations performed for obstructive prosthetic valve dysfunction. Between January 1994 and April 2005, 63 patients underwent reoperation for obstructive prosthetic valve dysfunction. The mean age of the patients was 40.3 +/- 12.8 years. The mitral valve was replaced in 47 (74.6%) patients, the aortic valve in 6 (9.5%) patients, and both valves in 10 (15.9%) patients. Forty-three (68.2%) patients underwent emergency reoperations. Early hospital mortality occurred in 13 (20.6%) patients. The ethiology of the valve dysfunction was pannus formation in 45 (71.4%) patients and thrombus formation in 18 (28.6%). Pannus and thrombus were localized at the atrial side of the prosthetic valve in 15 (23.9%) patients, at the ventricular side in 13 (20.6%), and at both sides in 35 (55.5%). Inadequate anticoagulation was diagnosed in 28 of 63 (44.4%) patients. The mean INR level in these 28 patients was 1.43 +/- 0.24. In multivariate analysis, the only risk factor for early hospital mortality was left ventricular ejection fraction (P = 0.015; Odds: 0.000, 95% CI: 0.000-0.043). It is concluded reoperations for prosthetic valve dysfunction have a high mortality rate. This study revealed that left ventricular dysfunction is the major determinant of surgical mortality in patients requiring reoperation for valve dysfunction due to pannus or thrombus.

Entities:  

Mesh:

Year:  2006        PMID: 16607051     DOI: 10.1536/ihj.47.237

Source DB:  PubMed          Journal:  Int Heart J        ISSN: 1349-2365            Impact factor:   1.862


  5 in total

1.  Limitations of multimodality imaging in the diagnosis of pannus formation in prosthetic aortic valve and review of the literature.

Authors:  Juan Bautista Soumoulou; Tomás Francisco Cianciulli; Andrea Zappi; Alberto Cozzarin; María Cristina Saccheri; Jorge Alberto Lax; Robert Guidoin; Ze Zhang
Journal:  World J Cardiol       Date:  2015-04-26

2.  Recurrent infarctions due to a dome-shaped pannus above the mitral valve prosthesis.

Authors:  Hirofumi Kasahara; Yoshito Inoue; Satoru Suzuki
Journal:  J Thorac Dis       Date:  2016-01       Impact factor: 2.895

Review 3.  Mechanical valve obstruction: Review of diagnostic and treatment strategies.

Authors:  Jason Salamon; Jerson Munoz-Mendoza; Jared J Liebelt; Cynthia C Taub
Journal:  World J Cardiol       Date:  2015-12-26

4.  Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

Authors:  Ahmad K Darwazah
Journal:  J Cardiothorac Surg       Date:  2012-06-29       Impact factor: 1.637

5.  Anesthetic management of a patient with obstructive prosthetic aortic valve dysfunction: a case report.

Authors:  Bo Ra Lee; Jeong-Rim Lee; Min Soo Kim
Journal:  Korean J Anesthesiol       Date:  2014-02-28
  5 in total