Literature DB >> 16603886

Intratester and intertester reliability of clinical measures of lower extremity anatomic characteristics: implications for multicenter studies.

Sandra J Shultz1, Anh-Dung Nguyen, Thomas C Windley, Anthony S Kulas, Timothy L Botic, Bruce D Beynnon.   

Abstract

OBJECTIVE: To determine whether multiple examiners could be trained to measure lower extremity anatomic characteristics with acceptable reliability and precision, both within (intratester) and between (intertester) testers. We also determined whether testers trained 18 months apart could perform these measurements with good agreement.
SETTING: University's Applied Neuromechanics Research Laboratory. PARTICIPANTS: Sixteen, healthy participants (7 men, 9 women). ASSESSMENT OF RISK FACTORS: Six investigators measured 12 anatomic characteristics on the right lower extremity in the Fall of 2004. Four testers underwent training immediately preceding the study, and measured subjects on 2 separate days to examine intratester reliability. Two testers trained 18 months before the study (Spring 2002) measured each subject on day 1 to examine the consistency of intertester reliability when testers are trained at different times. MAIN OUTCOME MEASUREMENTS: Knee laxity, genu recurvatum, quadriceps angle, tibial torsion, tibiofemoral angle, hamstring extensibility, pelvic angle, navicular drop, femur length, tibial length, and hip anteversion.
RESULTS: With few exceptions, all testers consistently measured each variable between test days (intraclass correlation coefficient>or=0.80). Intraclass correlation coefficient values were lower for intertester reliability (0.48 to 0.97), and improved from day 1 to day 2. Intertester reliability was similar when comparing testers trained 18 months before those trained immediately before the study. Absolute measurement error varied considerably across individual testers.
CONCLUSIONS: Multiple investigators can be trained at different times to measure anatomic characteristics with good to excellent intratester reliability. Intratester reliability did not always ensure acceptable intertester reliability or measurement precision, suggesting more training (or more experience) may be required to achieve acceptable measurement reliability and precision between multiple testers.

Entities:  

Mesh:

Year:  2006        PMID: 16603886     DOI: 10.1097/00042752-200603000-00012

Source DB:  PubMed          Journal:  Clin J Sport Med        ISSN: 1050-642X            Impact factor:   3.638


  33 in total

1.  Accuracy and inter-observer reliability of visual estimation compared to clinical goniometry of the elbow.

Authors:  Davide Blonna; Peter C Zarkadas; James S Fitzsimmons; Shawn W O'Driscoll
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-17       Impact factor: 4.342

2.  A Sex-Stratified Multivariate Risk Factor Model for Anterior Cruciate Ligament Injury.

Authors:  Bruce D Beynnon; Daniel R Sturnick; Erin C Argentieri; James R Slauterbeck; Timothy W Tourville; Sandra J Shultz; Pamela M Vacek
Journal:  J Athl Train       Date:  2015-09-04       Impact factor: 2.860

3.  Lower extremity kinematics in running athletes with and without a history of medial shin pain.

Authors:  Janice K Loudon; Michael P Reiman
Journal:  Int J Sports Phys Ther       Date:  2012-08

4.  Reliability and reference values of two clinical measurements of dynamic and static knee position in healthy children.

Authors:  Maria Ortqvist; Eva B Moström; Ewa M Roos; Pia Lundell; Per-Mats Janarv; Suzanne Werner; Eva W Broström
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-17       Impact factor: 4.342

5.  Posterior pelvic tilt is a risk factor for rectal prolapse: a propensity score matching analysis.

Authors:  C Cantiani; D Sgamma; E Grossi; D Saccá; O R Meli; Q Lai; F Gaj
Journal:  Tech Coloproctol       Date:  2020-03-13       Impact factor: 3.781

6.  Identifying relationships among lower extremity alignment characteristics.

Authors:  Anh-Dung Nguyen; Sandra J Shultz
Journal:  J Athl Train       Date:  2009 Sep-Oct       Impact factor: 2.860

7.  The Relationship Between Lower Extremity Alignment Characteristics and Anterior Knee Joint Laxity.

Authors:  Sandra J Shultz; Anh-Dung Nguyen; Beverly J Levine
Journal:  Sports Health       Date:  2009-01       Impact factor: 3.843

8.  Increased range of motion and function in an individual with breast cancer and necrotizing fasciitis-manual therapy and pulsed short-wave diathermy treatment.

Authors:  Wayne Johnson; David O Draper
Journal:  Case Rep Med       Date:  2010-07-14

9.  Various methods for assessing static lower extremity alignment: implications for prospective risk-factor screenings.

Authors:  Anh-Dung Nguyen; Michelle C Boling; Carrie A Slye; Emily M Hartley; Gina L Parisi
Journal:  J Athl Train       Date:  2013-02-20       Impact factor: 2.860

10.  Reliability and normative values for the foot mobility magnitude: a composite measure of vertical and medial-lateral mobility of the midfoot.

Authors:  Thomas G McPoil; Bill Vicenzino; Mark W Cornwall; Natalie Collins; Meghan Warren
Journal:  J Foot Ankle Res       Date:  2009-03-06       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.