Literature DB >> 16602315

A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism.

Markus Kohlhaas1, Eberhard Spoerl, Andreas G Boehm, Katharina Pollack.   

Abstract

PURPOSE: To create a correction formula to determine the real intraocular pressure (IOP) after LASIK considering the altered corneal thickness, corneal curvature, and corneal stability.
METHODS: This prospective clinical trial comprised 101 eyes of 59 patients (34 women and 25 men) that underwent LASIK with a mean preoperative spherical equivalent refraction of -6.3 +/- 2.17 diopters (D) (-3.0 to -11.5 D). Mean patient age was 32 +/- 9 years. Preoperatively and 6 months postoperatively, IOP (by Goldmann applanation tonometry), keratometry (by topography), and central corneal thickness (CCT) (by ultrasound pachymetry) were evaluated. These parameters were measured in all patients between 8 and 11 o'clock in the morning.
RESULTS: Due to the LASIK procedure, IOP was reduced from 16.5 +/- 2.1 mmHg (range: 12 to 22 mmHg) to 12.9 +/- 1.9 mmHg (range: 8 to 16 mmHg). Multiple linear regression analysis of the IOP values before and after LASIK showed a significant correlation between the measured IOP and CCT and keratometry values (R2=0.631; P<.001). After LASIK, the biomechanical bending strength of the cornea is reduced by the cut so that the measured IOP must be additionally corrected by 0.75 mmHg. An equation containing all three changes is given: IOP (real) = IOP (measured) + (540-CCT)/71 + (43-K-value)/2.7 + 0.75 mmHg.
CONCLUSIONS: Intraocular pressure measurements after LASIK for the correction of myopia are inaccurate as a consequence of changes in CCT, corneal curvature, and corneal flap stability. After LASIK, the measured IOP should be corrected to avoid false low IOP applanation readings.

Entities:  

Mesh:

Year:  2006        PMID: 16602315     DOI: 10.3928/1081-597X-20060301-11

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  15 in total

1.  Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery.

Authors:  Antonios P Aristeidou; Georgios Labiris; Andreas Katsanos; Michalis Fanariotis; Nikitas C Foudoulakis; Vassilios P Kozobolis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-06-25       Impact factor: 3.117

2.  Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia.

Authors:  Shirin Hamed-Azzam; Daniel Briscoe; Oren Tomkins; Raneen Shehedeh-Mashor; Hanna Garzozi
Journal:  Int Ophthalmol       Date:  2012-12-29       Impact factor: 2.031

3.  Comparison of intraocular pressures at different points in human's cornea before and after laser in situ keratomileusis with tono-pen tonometer.

Authors:  Xinyu Li; Guigang Li; Lei Liu; Jing Li
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2011-02-19

4.  A sample predictive model for intraocular pressure following laser in situ keratomileusis for myopia and an "intraocular pressure constant".

Authors:  Ayse Ebru Bahadir Kilavuzoglu; Tahir Kansu Bozkurt; Cemile Banu Cosar; Asım Bozkurt Sener
Journal:  Int Ophthalmol       Date:  2017-06-24       Impact factor: 2.031

5.  [Alterations in intraocular pressure and the CorVis parameters after LASIK].

Authors:  A Anton; M Neuburger; J F Jordan; T Wecker; J Lübke; S Heinzelmann; T Lapp; D Böhringer; T Reinhard; P Maier
Journal:  Ophthalmologe       Date:  2017-05       Impact factor: 1.059

6.  Post-LASIK interface fluid syndrome caused by steroid drops.

Authors:  Mahfouth A Bamashmus; Mahmoud F Saleh
Journal:  Saudi J Ophthalmol       Date:  2013-04-04

7.  Cornea microstructure and mechanical responses measured with nonlinear optical and optical coherence microscopy using sub-10-fs pulses.

Authors:  Qiaofeng Wu; Brian E Applegate; Alvin T Yeh
Journal:  Biomed Opt Express       Date:  2011-04-11       Impact factor: 3.732

8.  Comparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry.

Authors:  Isabel Cacho; Juan Sanchez-Naves; Laura Batres; Jesús Pintor; Gonzalo Carracedo
Journal:  J Ophthalmol       Date:  2015-06-08       Impact factor: 1.909

9.  A case of primary congenital glaucoma.

Authors:  Mohammad-Reza Razeghinejad; Jonathan S Myers; Arif O Khan; Ramin Daneshvar
Journal:  J Ophthalmic Vis Res       Date:  2013-07

10.  Factors Influencing Intraocular Pressure Changes after Laser In Situ Keratomileusis with Flaps Created by Femtosecond Laser or Mechanical Microkeratome.

Authors:  Meng-Yin Lin; David C K Chang; Yun-Dun Shen; Yen-Kuang Lin; Chang-Ping Lin; I-Jong Wang
Journal:  PLoS One       Date:  2016-01-29       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.