Literature DB >> 16600271

Determination of orthophthalaldehyde in air using 2,4-dinitrophenylhydrazine-impregnated silica cartridge and high-performance liquid chromatography.

Shigehisa Uchiyama1, Erika Matsushima, Hiroshi Tokunaga, Yasufumi Otsubo, Masanori Ando.   

Abstract

A new method is described for the determination of orthophthalaldehyde in air which is used for the disinfection of various instruments (e.g. endoscopes) in hospital. Orthophthalaldehyde in air was collected with a silica gel cartridge impregnated with acidified 2,4-dinitrophenylhydrazine (DNPH-cartridge) and derivatives were analyzed by high-performance liquid chromatography (HPLC). In this study, the derivatization was examined by comparing the process with three phthalaldehyde isomers (ortho-, iso- and tere-). In the case of iso- and tere-phthalaldehyde, derivatives synthesized with excess of aldehyde consisted mainly of mono-derivatives, and derivatives synthesized with excess of DNPH consisted mainly of bis-derivative. In the case of orthophthalaldehyde, derivative consisted of only bis-derivative and mono-derivative was never observed under any conditions. Orthophthalaldehyde was completely retained by the DNPH-cartridge during air sampling, however, the derivatization reaction was incomplete and unreacted orthophthalaldehyde was flushed from the cartridge during the subsequent solvent extraction process. Unreacted orthophthalaldehyde and DNPH reacted again in the extraction solvent solution. Immediately after the solvent extraction, both mono- and bis-DNPhydrazone derivatives of orthophthalaldehyde were present in the solution. However, over time, the mono-derivative decreased and bis-derivative increased until only the bis-derivative was left allowing accurate determination of the orthophthalaldehyde concentration. The transformation of mono-derivative to bis-derivative was faster in polar aprotic solvents such as acetonitrile, dimethyl sulfoxide and ethyl acetate. Transformation was found to occur most quickly in acetonitrile solvent and was completed in 4 h in this case. It was possible to measure orthophthalaldehyde in air as bis-derivative using a DNPH impregnated silica cartridge and HPLC analysis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16600271     DOI: 10.1016/j.chroma.2006.03.059

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Characterization of Exposure to Cleaning Agents Among Health Workers in Two Southern African Tertiary Hospitals.

Authors:  H H Mwanga; R Baatjies; M F Jeebhay
Journal:  Ann Work Expo Health       Date:  2022-10-11       Impact factor: 2.779

2.  Development, evaluation and comparison of two independent sampling and analytical methods for ortho-phthalaldehyde vapors and condensation aerosols in air.

Authors:  Samuel P Tucker
Journal:  Anal Methods       Date:  2014-02-25       Impact factor: 2.896

3.  Bach adsorption study for the extraction of silver ions by hydrazone compounds from aqueous solution.

Authors:  Abdussalam Salhin Mohamad Ali; Norfarhah Abdul Razak; Ismail Ab Rahman
Journal:  ScientificWorldJournal       Date:  2012-04-26

4.  Development of a measurement method to determine the ceiling exposure concentration of ortho-phthalaldehyde handling workers.

Authors:  Shinobu Yamamoto; Akito Takeuchi; Toru Ishidao; Hiroaki Ohkuma; Masayoshi Ichiba; Hajime Hori
Journal:  J Occup Health       Date:  2019-12-28       Impact factor: 2.708

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.