Partial-k-space acquisition method for improved SNR efficiency and temporal resolution in 3D fMRI.

Y Hu1, G H Glover.   

Abstract

Previous studies have shown the relative importance of physiological noise and thermal noise in 2D MR images. Since physiological noise is proportional to the signal, it can be the dominant component at the center of k-space. In this study we demonstrate that the signal-to-noise ratio (SNR) efficiency and temporal resolution for 3D functional MRI (fMRI) are increased by the use of a partial-k-space acquisition method. In partial-k-space methods, the high-spatial-frequency components are doubled in amplitude during reconstruction, resulting in twice as much noise from those components. However, in sum these contributions are relatively small compared to those at the low spatial frequencies, where physiological noise is dominant. Therefore, the effect on the final MR images is almost negligible due to the square summation rule. Thus, the partial-k-space 3D method sacrifices much less SNR than is expected from the thermal noise model, and the SNR efficiency is increased compared to a full-k-space acquisition since more time frames can be collected for the same scan time. Accordingly, the temporal resolution can be increased in 3D acquisitions because only partial coverage of k-space is necessary. Experimental results confirm that more activation with a higher average t-score is detected by this method. Copyright (c) 2006 Wiley-Liss, Inc.

Mesh:

Year:  2006        PMID: 16598724     DOI: 10.1002/mrm.20877

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Whole-brain three-dimensional T2-weighted BOLD functional magnetic resonance imaging at 7 Tesla.

Authors:  Jun Hua; Qin Qin; Peter C M van Zijl; James J Pekar; Craig K Jones
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

2.  Variable-density spiral-in/out functional magnetic resonance imaging.

Authors:  Catie Chang; Gary H Glover
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

3.  EPI distortion correction for concurrent human brain stimulation and imaging at 3T.

Authors:  Hyuntaek Oh; Jung Hwan Kim; Jeffrey M Yau
Journal:  J Neurosci Methods       Date:  2019-08-18       Impact factor: 2.390

4.  Evaluation of partial k-space strategies to speed up time-domain EPR imaging.

Authors:  Sankaran Subramanian; Gadisetti V R Chandramouli; Alan McMillan; Rao P Gullapalli; Nallathamby Devasahayam; James B Mitchell; Shingo Matsumoto; Murali C Krishna
Journal:  Magn Reson Med       Date:  2012-10-08       Impact factor: 4.668

5.  The impact of physiological noise correction on fMRI at 7 T.

Authors:  C Hutton; O Josephs; J Stadler; E Featherstone; A Reid; O Speck; J Bernarding; N Weiskopf
Journal:  Neuroimage       Date:  2011-04-15       Impact factor: 6.556

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.