Literature DB >> 16598491

[The AGILITY ankle: mid- and long-term results].

F G Alvine1, S F Conti.   

Abstract

The AGILITY ankle has been clinically used for over 20 years and between the two authors, a total of 1,075 AGILITY ankles have been inserted. Beside concept and design of this unique ankle prosthesis, specific follow-up data will be presented on 775 implants performed by the first author (FGA). The AGILITY Ankle System can give reliable and predictable results if the surgeon is aware of the complexity of this operation and the need for careful postoperative monitoring. Many of the failures that have occurred in the Agility System can be prevented by early detection (i.e., syndesmotic nonunion, hindfoot valgus, fractures, etc.) and if the problem is corrected, the implant can be maintained. The new LP System will also add another dimension to the overall adaptability of the prosthesis for an additional broader base of patients.

Entities:  

Mesh:

Year:  2006        PMID: 16598491     DOI: 10.1007/s00132-006-0939-5

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  3 in total

1.  Intraoperative measurement of distraction for ligament tensioning in total ankle arthroplasty.

Authors:  Terence E McIff; Frank G Alvine; Charles L Saltzman; Jay C Klaren; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2004-07       Impact factor: 4.176

2.  Total ankle arthroplasty: a unique design. Two to twelve-year follow-up.

Authors:  M T Pyevich; C L Saltzman; J J Callaghan; F G Alvine
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

3.  The Agility total ankle arthroplasty. Seven to sixteen-year follow-up.

Authors:  Stephen I Knecht; Miriam Estin; John J Callaghan; Miriam B Zimmerman; Kyle J Alliman; Frank G Alvine; Charles L Saltzman
Journal:  J Bone Joint Surg Am       Date:  2004-06       Impact factor: 5.284

  3 in total
  2 in total

1.  Accuracy assessment of measuring component position after total ankle arthroplasty using a conventional method.

Authors:  Kyoung-Jai Lee; Shao-Hua Wang; Gun-Woo Lee; Keun-Bae Lee
Journal:  J Orthop Surg Res       Date:  2017-07-31       Impact factor: 2.359

2.  Clinical efficacy of the Ankle Spacer for the treatment of multiple secondary osteochondral lesions of the talus.

Authors:  Jari Dahmen; J Nienke Altink; Gwendolyn Vuurberg; Coen A Wijdicks; Sjoerd As Stufkens; Gino Mmj Kerkhoffs
Journal:  World J Orthop       Date:  2022-02-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.