Literature DB >> 16596534

ProCol vascular bioprosthesis for vascular access: midterm results.

A Hatzibaloglou1, I Velissaris, D Kaitzis, D Grekas, A Avdelidou, D Kiskinis.   

Abstract

BACKGROUND/AIMS: This study aimed to evaluate the safety and efficacy of the ProCol vascular bioprostheses as vascular access (VA) material, especially in patients with a history of prior failed access.
METHODS: During a 20-month period, 25 arteriovenous (AV) bovine vein grafts were placed in 24 hemodialysis (HD) patients for VA. All patients presented with failed autologous access sites.
RESULTS: Graft placement was successful in all patients with no procedure-related complications. Follow-up from 6-26 months gave primary 6-month, 12-month and 24-month patency rates of, respectively, 90%, 80% and 70%. Graft characteristics in cannulation and hemostasis were very satisfying.
CONCLUSION: Our midterm results demonstrated that the ProCol vascular bioprosthesis was a promising material for VA with good patency and low complication rates.

Entities:  

Year:  2004        PMID: 16596534     DOI: 10.1177/112972980400500104

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  5 in total

Review 1.  Small Diameter Xenogeneic Extracellular Matrix Scaffolds for Vascular Applications.

Authors:  Manuela Lopera Higuita; Leigh G Griffiths
Journal:  Tissue Eng Part B Rev       Date:  2019-11-27       Impact factor: 6.389

Review 2.  Neointimal hyperplasia associated with synthetic hemodialysis grafts.

Authors:  Li Li; Christi M Terry; Yan-Ting E Shiu; Alfred K Cheung
Journal:  Kidney Int       Date:  2008-07-30       Impact factor: 10.612

3.  Bioengineered human acellular vessels for dialysis access in patients with end-stage renal disease: two phase 2 single-arm trials.

Authors:  Jeffrey H Lawson; Marc H Glickman; Marek Ilzecki; Tomasz Jakimowicz; Andrzej Jaroszynski; Eric K Peden; Alison J Pilgrim; Heather L Prichard; Malgorzata Guziewicz; Stanisław Przywara; Jacek Szmidt; Jakub Turek; Wojciech Witkiewicz; Norbert Zapotoczny; Tomasz Zubilewicz; Laura E Niklason
Journal:  Lancet       Date:  2016-05-14       Impact factor: 79.321

Review 4.  Clinical results of biologic prosthesis: A systematic review and meta-analysis of comparative studies.

Authors:  Chumpon Wilasrusmee; Boonying Siribumrungwong; Suthas Horsirimanont; Napaphat Poprom; Jakrapan Jirasiritham; Ammarin Thakkinstian
Journal:  Ann Med Surg (Lond)       Date:  2017-01-25

Review 5.  Current Strategies for the Manufacture of Small Size Tissue Engineering Vascular Grafts.

Authors:  Michele Carrabba; Paolo Madeddu
Journal:  Front Bioeng Biotechnol       Date:  2018-04-17