Literature DB >> 16594298

Simple two-electrode biosignal amplifier.

D Dobrev1, T Neycheva, N Mudrov.   

Abstract

A simple, cost effective circuit for a two-electrode non-differential biopotential amplifier is proposed. It uses a 'virtual ground' transimpedance amplifier and a parallel RC network for input common mode current equalisation, while the signal input impedance preserves its high value. With this innovative interface circuit, a simple non-inverting amplifier fully emulates high CMRR differential. The amplifier equivalent CMRR (typical range from 70-100 dB) is equal to the open loop gain of the operational amplifier used in the transimpedance interface stage. The circuit has very simple structure and utilises a small number of popular components. The amplifier is intended for use in various two-electrode applications, such as Holter-type monitors, defibrillators, ECG monitors, biotelemetry devices etc.

Mesh:

Year:  2005        PMID: 16594298     DOI: 10.1007/bf02430949

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  8 in total

1.  Two-electrode biopotential amplifier with current-driven inputs.

Authors:  D Dobrev; I Daskalov
Journal:  Med Biol Eng Comput       Date:  2002-01       Impact factor: 2.602

2.  Two-electrode non-differential biopotential amplifier.

Authors:  D Dobrev
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

3.  Two-electrode low supply voltage electrocardiogram signal amplifier.

Authors:  D Dobrev
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

Review 4.  Developments in ECG acquisition, preprocessing, parameter measurement, and recording.

Authors:  I K Daskalov; I A Dotsinsky; I I Christov
Journal:  IEEE Eng Med Biol Mag       Date:  1998 Mar-Apr

5.  New approach to the digital elimination of 50 Hz interference from the electrocardiogram.

Authors:  I I Christov; I A Dotsinsky
Journal:  Med Biol Eng Comput       Date:  1988-07       Impact factor: 2.602

6.  Ground-free ECG recording with two electrodes.

Authors:  N V Thakor; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1980-12       Impact factor: 4.538

7.  Reduction of interference due to common mode voltage in biopotential amplifiers.

Authors:  B B Winter; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1983-01       Impact factor: 4.538

8.  Removal of power-line interference from the ECG: a review of the subtraction procedure.

Authors:  Chavdar Levkov; Georgy Mihov; Ratcho Ivanov; Ivan Daskalov; Ivaylo Christov; Ivan Dotsinsky
Journal:  Biomed Eng Online       Date:  2005-08-23       Impact factor: 2.819

  8 in total
  3 in total

1.  Bootstrapped two-electrode biosignal amplifier.

Authors:  Dobromir Petkov Dobrev; Tatyana Neycheva; Nikolay Mudrov
Journal:  Med Biol Eng Comput       Date:  2008-02-12       Impact factor: 2.602

2.  Estimation of stray coupling capacitances in biopotential measurements.

Authors:  Marcelo Haberman; Augusto Cassino; Enrique Spinelli
Journal:  Med Biol Eng Comput       Date:  2011-07-20       Impact factor: 2.602

3.  Adaptive swarm cluster-based dynamic multi-objective synthetic minority oversampling technique algorithm for tackling binary imbalanced datasets in biomedical data classification.

Authors:  Jinyan Li; Simon Fong; Yunsick Sung; Kyungeun Cho; Raymond Wong; Kelvin K L Wong
Journal:  BioData Min       Date:  2016-12-01       Impact factor: 2.522

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.