| Literature DB >> 16594212 |
M H Hamilton1, S J Langley Hobbs.
Abstract
The use of the AO (Arbeitsgemeinschaft für Osteosynthesefragen) veterinary mini 'T'-plate for stabilisation of distal radius and ulna fractures in toy breed dogs was evaluated in a retrospective study. All of the 14 dogs in the study weighed 3.5 kg or less. The AO mini 'T'-plate was used as the final means of fixation in all cases. It was used as the primary form of stabilisation in ten dogs, and in four dogs it was used at revision surgery. In all cases, of the fractures healed. Return to function was graded 'as excellent' in six cases, 'good' in four and 'fair' in two. Two dogs were lost to long-term follow up. It was concluded that the AO veterinary mini 'T'-plate is a suitable choice of implant for stabilisation of distal radius and ulna fractures in toy breed dogs, especially when the distal fragment is very small.Entities:
Mesh:
Year: 2005 PMID: 16594212
Source DB: PubMed Journal: Vet Comp Orthop Traumatol ISSN: 0932-0814 Impact factor: 1.358