Literature DB >> 16590311

THE APPLICATION OF THE FICK PRINCIPLE TO THE MEASUREMENT OF PULMONARY BLOOD FLOW.

H W Fritts1, A Cournand.   

Abstract

Year:  1958        PMID: 16590311      PMCID: PMC528697          DOI: 10.1073/pnas.44.10.1079

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


× No keyword cloud information.
  5 in total

1.  The fate of circulating lactic acid in the human lung.

Authors:  A M MITCHELL; A COURNAND
Journal:  J Clin Invest       Date:  1955-03       Impact factor: 14.808

2.  Discrepancies in cardiac output measurements by two applications of the direct Fick principle.

Authors:  G G NAHAS; M B VISSCHER; F J HADDY
Journal:  J Appl Physiol       Date:  1953-11       Impact factor: 3.531

3.  The Fick principle: analysis of potential errors in its conventional application.

Authors:  M B VISSCHER; J A JOHNSON
Journal:  J Appl Physiol       Date:  1953-04       Impact factor: 3.531

4.  Comparison of cardiac output determined by the ballistocardiograph (Nickerson apparatus) and by the direct Fick method.

Authors:  R T CATHCART; W W FIELD; D W RICHARDS
Journal:  J Clin Invest       Date:  1953-01       Impact factor: 14.808

5.  Effects of acute anoxia on the circulation and respiration in patients with chronic pulmonary disease studied during the steady state.

Authors:  A P FISHMAN; J McCLEMENT; A HIMMELSTEIN; A COURNAND
Journal:  J Clin Invest       Date:  1952-08       Impact factor: 14.808

  5 in total
  5 in total

1.  Estimation of right ventricular output in man using radioactive krypton (Kr85).

Authors:  D F ROCHESTER; J DURAND; J O PARKER; H W FRITTS; R M HARVEY
Journal:  J Clin Invest       Date:  1961-04       Impact factor: 14.808

Review 2.  Measurement of the cardiac output in man.

Authors:  S H Taylor
Journal:  Proc R Soc Med       Date:  1966

3.  Catheter-directed ultrasound-accelerated thrombolysis may be life-saving in patients with massive pulmonary embolism after failed systemic thrombolysis.

Authors:  Saim Sag; Omer Fatih Nas; Aysel Aydin Kaderli; Bulent Ozdemir; İbrahim Baran; Cuneyt Erdoğan; Sumeyye Gullulu; Bahattin Hakyemez; Ali Aydinlar
Journal:  J Thromb Thrombolysis       Date:  2016-10       Impact factor: 2.300

4.  Variability in measures of exhaled breath na, influence of pulmonary blood flow and salivary na.

Authors:  Courtney M Wheatley; Nicholas A Cassuto; William T Foxx-Lupo; Eric M Snyder
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2010-08-27

Review 5.  Pulmonary Vascular Resistance Measurement Remains Keystone in Congenital Heart Disease Management.

Authors:  Omar Tamimi; Mohammed H A Mohammed
Journal:  Front Cardiovasc Med       Date:  2021-03-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.