Peripheral dose from uniform dynamic multileaf collimation fields: implications for sliding window intensity-modulated radiotherapy.

D S Sharma1, S S Deshpande, R D Phurailatpam, D D Deshpande, S K Shrivastava, K A Dinshaw.   

Abstract

The increase in the number of monitor units in sliding window intensity-modulated radiotherapy, compared with conventional techniques for the same target dose, may lead to an increase in peripheral dose (PD). PD from a linear accelerator was measured for 6 MV X-ray using 0.6 cm3 ionization chamber inserted at 5 cm depth into a 35 cm x 35 cm x 105 cm plastic water phantom. Measurements were made for field sizes of 6 cm x 6 cm, 10 cm x 10 cm and 14 cm x 14 cm, shaped in both static and dynamic multileaf collimation (DMLC) mode, employing strip fields of fixed width 0.5 cm, 1.0 cm, 1.5 cm, and 2.0 cm, respectively. The effect of collimator rotation and depth of measurement on peripheral dose was investigated for 10 cm x 10 cm field. Dynamic fields require 2 to 14 times the number of monitor units than does a static open field for the same dose at the isocentre, depending on strip field width and field size. Peripheral dose resulting from dynamic fields manifests two distinct regions showing a crest and trough within 30 cm from the field edge and a steady exponential fall beyond 30 cm. All dynamic fields were found to deliver a higher PD compared with the corresponding static open fields, being highest for smallest strip field width and largest field size; also, the percentage increase observed was highest at the largest out-of-field distance. For 6 cm x 6 cm field, dynamic fields with 0.5 cm and 2 cm strip field width deliver PDs 8 and 2 times higher than that of the static open field. The corresponding factors for 14 cm x 14 cm field were 15 and 6, respectively. The factors by which PD for DMLC fields increase, relative to jaws-shaped static fields for out-of-field distance beyond 30 cm, are almost the same as the corresponding increases in the number of monitor units. Reductions of 20% and 40% in PD were observed when the measurements were done at a depth of 10 cm and 15 cm, respectively. When the multileaf collimator executes in-plane (collimator 90 degrees) motion, peripheral dose decreases by as much as a factor of 3 compared with cross-plane data. The knowledge of PD from DMLC field is necessary to estimate the increase in whole-body dose and the likelihood of radiation induced secondary malignancy.

Entities:  

Mesh:

Year:  2006        PMID: 16585727     DOI: 10.1259/bjr/16208090

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

1.  Conceptus dose from involved-field radiotherapy for Hodgkin's lymphoma on a linear accelerator equipped with MLCs.

Authors:  Michalis Mazonakis; Efrossini Lyraraki; Charalambos Varveris; Elina Samara; Kyveli Zourari; John Damilakis
Journal:  Strahlenther Onkol       Date:  2009-06-09       Impact factor: 3.621

Review 2.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

3.  Consideration of the radiation dose delivered away from the treatment field to patients in radiotherapy.

Authors:  Michael L Taylor; Tomas Kron
Journal:  J Med Phys       Date:  2011-04

Review 4.  Cancer risk assessment in modern radiotherapy workflow with medical big data.

Authors:  Fu Jin; Huan-Li Luo; Juan Zhou; Ya-Nan He; Xian-Feng Liu; Ming-Song Zhong; Han Yang; Chao Li; Qi-Cheng Li; Xia Huang; Xiu-Mei Tian; Da Qiu; Guang-Lei He; Li Yin; Ying Wang
Journal:  Cancer Manag Res       Date:  2018-06-22       Impact factor: 3.989

5.  Evaluation of Breast Cancer Radiation Therapy Techniques in Outfield Organs of Rando Phantom with Thermoluminescence Dosimeter.

Authors:  M Behmadi; H Gholamhosseinian; M Mohammadi; Sh Naseri; M Momennezhad; Sh Bayani; M T Bahreyni Toossi
Journal:  J Biomed Phys Eng       Date:  2019-04-01

6.  Can volumetric modulated arc radiation therapy reduce organ at risk dose in stage 4 sinonasal tumors in dogs treated with boost irradiation?

Authors:  Valeria Meier; Felicitas Czichon; Linda Walsh; Carla Rohrer Bley
Journal:  PLoS One       Date:  2021-10-29       Impact factor: 3.240

7.  Peripheral dose measurements with diode and thermoluminescence dosimeters for intensity modulated radiotherapy delivered with conventional and un-conventional linear accelerator.

Authors:  Rajesh Kinhikar; Poonam Gamre; Chandrashekhar Tambe; Sudarshan Kadam; George Biju; C S Magai; Dipak Dhote; Shyam Shrivastava; Deepak Deshpande
Journal:  J Med Phys       Date:  2013-01

8.  Peripheral dose measurements in cervical cancer radiotherapy: a comparison of volumetric modulated arc therapy and step-and-shoot IMRT techniques.

Authors:  Ming X Jia; Xu Zhang; Ce Yin; Ge Feng; Na Li; Song Gao; Da W Liu
Journal:  Radiat Oncol       Date:  2014-02-21       Impact factor: 3.481

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.