Literature DB >> 16581152

Fast normalized cross correlation for motion tracking using basis functions.

A J H Hii1, C E Hann, J G Chase, E E W Van Houten.   

Abstract

Digital image-based elasto-tomography (DIET) is an emerging method for non-invasive breast cancer screening. Effective clinical application of the DIET system requires highly accurate motion tracking of the surface of an actuated breast with minimal computation. Normalized cross correlation (NCC) is the most robust correlation measure for determining similarity between points in two or more images providing an accurate foundation for motion tracking. However, even using fast Fourier transform (FFT) methods, it is too computationally intense for rapidly managing several large images. A significantly faster method of calculating the NCC is presented that uses rectangular approximations in place of randomly placed landmark points or the natural marks on the breast. These approximations serve as an optimal set of basis functions that are automatically detected, dramatically reducing computational requirements. To prove the concept, the method is shown to be 37-150 times faster than the FFT-based NCC with the same accuracy for simulated data, a visco-elastic breast phantom experiment and human skin. Clinically, this approach enables thousands of randomly placed points to be rapidly and accurately tracked providing high resolution for the DIET system.

Entities:  

Mesh:

Year:  2006        PMID: 16581152     DOI: 10.1016/j.cmpb.2006.02.007

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  5 in total

1.  Dynamic near-infrared imaging reveals transient phototropic change in retinal rod photoreceptors.

Authors:  Rongwen Lu; Alexander M Levy; Qiuxiang Zhang; Steven J Pittler; Xincheng Yao
Journal:  J Biomed Opt       Date:  2013-10       Impact factor: 3.170

2.  A fast normalized cross-correlation calculation method for motion estimation.

Authors:  Jianwen Luo; Elisa Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-06       Impact factor: 2.725

3.  Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

Authors:  Yilin Liu; Fang-Fang Yin; DongJoo Rhee; Jing Cai
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

4.  Computational burden resulting from image recognition of high resolution radar sensors.

Authors:  Patricia López-Rodríguez; Raúl Fernández-Recio; Ignacio Bravo; Alfredo Gardel; José L Lázaro; Elena Rufo
Journal:  Sensors (Basel)       Date:  2013-04-22       Impact factor: 3.576

5.  Evaluation of diastolic function by three-dimensional volume tracking of the mitral annulus with cardiovascular magnetic resonance: comparison with tissue Doppler imaging.

Authors:  Vincent Wu; Janice Y Chyou; Sohae Chung; Sharath Bhagavatula; Leon Axel
Journal:  J Cardiovasc Magn Reson       Date:  2014-09-20       Impact factor: 5.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.