Soo-Youn Lee1, Hyeon Ju Oh, Jong Won Kim, Yoon Gyoon Kim, Chul Jin Moon, Eun Hee Lee.
Abstract
We developed and validated a simple, rapid, and accurate HPLC-MS/MS method with simple protein precipitation for the determination of orphenadrine. Injection-to-injection running time was 3 min with a retention time of orphenadrine of 1.1 min. The linear assay range was 1-200 ng/mL (r2 > 0.99). The intra- and inter-assay imprecisions were CV 0.6-4.2% and CV 1.6-6.1%, respectively. The accuracy, extraction recovery, specificity and stability were satisfactory. Using the measured plasma concentrations of orphenadrine in 24 healthy subjects, pharmacokinetic profiles of orphenadrine were evaluated (AUC(0-72,) 1565+/-731 ng h/mL, Cmax 82.8+/-26.2 ng/mL, Tmax 3.0+/-0.9 h, elimination half-life 25.8+/-10.3 h).Entities:
Mesh:
Substances:
Year: 2006 PMID: 16580894 DOI: 10.1016/j.jchromb.2006.02.056
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205