Literature DB >> 16580448

Stentless bioprostheses improve postoperative coronary flow more than stented prostheses after valve replacement for aortic stenosis.

Farhad Bakhtiary1, Mirko Schiemann, Omer Dzemali, Thomas Wittlinger, Mirko Doss, Hans Ackermann, Anton Moritz, Peter Kleine.   

Abstract

OBJECTIVE: In some randomized studies, stentless aortic valves have demonstrated hemodynamic advantages in comparison with stented prostheses. The effect of more physiologic flow dynamics on coronary artery flow has not been investigated yet. This study compares coronary perfusion after aortic valve replacement with stented or stentless porcine bioprostheses in a prospective randomized study.
METHODS: A total of 24 patients (73 +/- 6 years) referred for treatment of aortic stenosis were randomized to aortic valve replacement with stented (Medtronic Mosaic; (Medtronic Inc, Minneapolis, Minn) or stentless (Medtronic Freestyle; Medtronic Inc) prostheses. Coronary flow was measured by means of magnetic resonance imaging preoperatively, 5 days after the operation, and 6 months postoperatively, then with evaluation of coronary flow reserve. Echocardiography was performed to quantify transvalvular gradients and left ventricular mass regression.
RESULTS: Coronary flow increased in both groups significantly (P < .001) after aortic valve replacement. This increase was higher in the stentless group compared with that seen in the stented group (343 +/- 137 vs 221 +/- 66 mL/min). Also, coronary flow reserve was higher for stentless valves (3.4 +/- 0.3 for stentless valves and 2.3 +/- 0.1 for stented valves). Mean pressure gradients for Freestyle valves were lower (10 +/- 4 and 8 +/- 3 mm Hg, respectively, vs 19 +/- 6 postoperatively and 15 +/- 4 mm Hg at follow-up for Mosaic valves, P < .05). Left ventricular mass regression was similar in both groups.
CONCLUSIONS: Normalization of coronary artery flow after aortic valve replacement for aortic stenosis was more pronounced for stentless valves compared with stented valves. The fact that the stentless design also demonstrated a superior hemodynamic performance with lower pressure gradients might be explained by the design being closer to physiologic anatomy and thus the presence of lower turbulence levels in the sinuses of Valsalva.

Entities:  

Mesh:

Year:  2006        PMID: 16580448     DOI: 10.1016/j.jtcvs.2005.10.055

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Stentless aortic valves. Current aspects.

Authors:  J Ennker; A Albert; I C Ennker
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2012

2.  To fly as a pilot after cardiac surgery.

Authors:  Thomas Syburra; Ed Nicol; Stuart Mitchell; Denis Bron; Ulrich Rosendahl; John Pepper
Journal:  Eur J Cardiothorac Surg       Date:  2018-03-01       Impact factor: 4.191

3.  Non-coronary cardiac surgery and percutaneous cardiology procedures in aircrew.

Authors:  Norbert Guettler; Edward D Nicol; Joanna d'Arcy; Rienk Rienks; Dennis Bron; Eddie D Davenport; Olivier Manen; Gary Gray; Thomas Syburra
Journal:  Heart       Date:  2019-01       Impact factor: 5.994

4.  Sutureless Perceval Aortic Valve Versus Conventional Stented Bioprostheses: Meta-Analysis of Postoperative and Midterm Results in Isolated Aortic Valve Replacement.

Authors:  Massimo Meco; Andrea Montisci; Antonio Miceli; Paolo Panisi; Francesco Donatelli; Silvia Cirri; Matteo Ferrarini; Antonio Lio; Mattia Glauber
Journal:  J Am Heart Assoc       Date:  2018-02-16       Impact factor: 5.501

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.