Literature DB >> 16579609

TNT detection using multiplexed liquid array displacement immunoassays.

George P Anderson1, Solimar C Moreira, Paul T Charles, Igor L Medintz, Ellen R Goldman, Mazyar Zeinali, Chris R Taitt.   

Abstract

The presence of trace contamination of soil and groundwater with explosives is an ongoing concern, for which improved methods are required to facilitate their detection and quantification. This is true both for the monitoring of remediation and for site characterization. Immunosensors have been found effective for solution-phase detection of environmental contaminants. Our work utilized the Luminex100 (flow cytometer) to detect TNT in a multiplexed displacement immunoassay format. The Luminex100 can perform a multiplexed assay by discriminating between up to 100 different bead sets. We used this capability to evaluate four different TNT monoclonal antibodies, two recombinant TNT antibodies, and a control antibody simultaneously for the rapid detection of TNT and other nitroaromatics. TNT could be detected at 0.1 ppb and quantified over the range of 1.0 ppb to 10 ppm. In addition, the assay was shown to be effective in various matrixes such as lake water, seawater, and acetone extracts of soil. Seawater required dilution with two parts buffer to avoid loss of microspheres, while the acetone extracts were diluted 100-fold or more to minimize solvent affects.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16579609     DOI: 10.1021/ac051995c

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Self-assembled nanoparticle arrays for multiphase trace analyte detection.

Authors:  Michael P Cecchini; Vladimir A Turek; Jack Paget; Alexei A Kornyshev; Joshua B Edel
Journal:  Nat Mater       Date:  2012-11-18       Impact factor: 43.841

2.  A general electrochemical method for label-free screening of protein-small molecule interactions.

Authors:  Kevin J Cash; Francesco Ricci; Kevin W Plaxco
Journal:  Chem Commun (Camb)       Date:  2009-08-28       Impact factor: 6.222

3.  Selectivity and Specificity: Pros and Cons in Sensing.

Authors:  William J Peveler; Mahdieh Yazdani; Vincent M Rotello
Journal:  ACS Sens       Date:  2016-09-30       Impact factor: 7.711

4.  Simultaneous Detection of Fenitrothion and Chlorpyrifos-Methyl with a Photonic Suspension Array.

Authors:  Xuan Wang; Zhongde Mu; Fengqi Shangguan; Ran Liu; Yuepu Pu; Lihong Yin
Journal:  PLoS One       Date:  2013-06-21       Impact factor: 3.240

5.  Detection of fumonisin b1 and ochratoxin a in grain products using microsphere-based fluid array immunoassays.

Authors:  George P Anderson; Vasudha A Kowtha; Chris R Taitt
Journal:  Toxins (Basel)       Date:  2010-02-25       Impact factor: 4.546

6.  Fluorescence-based sensing of 2,4,6-trinitrotoluene (TNT) using a multi-channeled poly(methyl methacrylate) (PMMA) microimmunosensor.

Authors:  Paul T Charles; Andre A Adams; Peter B Howell; Scott A Trammell; Jeffrey R Deschamps; Anne W Kusterbeck
Journal:  Sensors (Basel)       Date:  2010-01-22       Impact factor: 3.576

7.  Colorimetric-based detection of TNT explosives using functionalized silica nanoparticles.

Authors:  Noorhayati Idros; Man Yi Ho; Mike Pivnenko; Malik M Qasim; Hua Xu; Zhongze Gu; Daping Chu
Journal:  Sensors (Basel)       Date:  2015-06-03       Impact factor: 3.576

8.  A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin.

Authors:  Tzu-Cheng Sung; Wen-Yih Chen; Pramod Shah; Chien-Sheng Chen
Journal:  Sci Rep       Date:  2016-02-23       Impact factor: 4.379

Review 9.  Single Domain Antibodies as New Biomarker Detectors.

Authors:  Chiuan Herng Leow; Katja Fischer; Chiuan Yee Leow; Qin Cheng; Candy Chuah; James McCarthy
Journal:  Diagnostics (Basel)       Date:  2017-10-17

10.  Fast Detection of 2,4,6-Trinitrotoluene (TNT) at ppt Level by a Laser-Induced Immunofluorometric Biosensor.

Authors:  Martin Paul; Georg Tscheuschner; Stefan Herrmann; Michael G Weller
Journal:  Biosensors (Basel)       Date:  2020-08-05
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.