Literature DB >> 16574606

Indicators of moisture and ventilation system contamination in U.S. office buildings as risk factors for respiratory and mucous membrane symptoms: analyses of the EPA BASE data.

Mark J Mendell1, Myrna Cozen, Quanhong Lei-Gomez, Howard S Brightman, Christine A Erdmann, John R Girman, Susan E Womble.   

Abstract

We assessed associations between indicators for moisture in office buildings and weekly, building-related lower respiratory and mucous membrane symptoms in office workers, using the U.S. EPA BASE data, collected in a representative sample of 100 U.S. office buildings. We estimated the strength of associations between the symptom outcomes and moisture indicators in multivariate logistic regression models as odds ratios (ORs) and 95% confidence intervals (CI), controlling for potential confounding factors and adjusting for correlation among workers in buildings. This analysis identified associations between building-related symptoms and several indicators of moisture or contamination in office buildings. One set of models showed almost a tripling of weekly building-related lower respiratory symptoms in association with lack of cleaning of the drip pans under air-conditioning cooling coils (OR [CI] = 2.8 (1.2-6.5)). Other models found that lack of cleaning of either drip pans or cooling coils was associated with increased mucous membrane symptoms (OR [CI] = 1.4 (1.1-1.9)). Slightly increased symptoms were also associated with other moisture indicators, especially mucous membrane symptoms and past water damage to building mechanical rooms (OR [CI] = 1.3 (1.0-1.7)). Overall, these findings suggest that the presence of moisture or contamination in ventilation systems or occupied spaces in office buildings may have adverse respiratory or irritant effects on workers. The analysis, however, failed to confirm several risks identified in a previous study, such as condition of drain pans or outdoor air intakes, and other hypothesized moisture risks. Studies with more rigorous measurement of environmental risks and health outcomes will be necessary to define moisture-related risks in buildings.

Mesh:

Substances:

Year:  2006        PMID: 16574606     DOI: 10.1080/15459620600628589

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  3 in total

1.  Automated cleaning of fan coil units with a natural detergent-disinfectant product.

Authors:  Giorgio Liguori; Maria Bagattini; Francesca Gallè; Mario Negrone; Valeria Di Onofrio; Maria Triassi
Journal:  Ann Clin Microbiol Antimicrob       Date:  2010-10-12       Impact factor: 3.944

2.  Impact of cabin ozone concentrations on passenger reported symptoms in commercial aircraft.

Authors:  Gabriel Bekö; Joseph G Allen; Charles J Weschler; Jose Vallarino; John D Spengler
Journal:  PLoS One       Date:  2015-05-26       Impact factor: 3.240

3.  Abridged version of the AWMF guideline for the medical clinical diagnostics of indoor mould exposure: S2K Guideline of the German Society of Hygiene, Environmental Medicine and Preventive Medicine (GHUP) in collaboration with the German Association of Allergists (AeDA), the German Society of Dermatology (DDG), the German Society for Allergology and Clinical Immunology (DGAKI), the German Society for Occupational and Environmental Medicine (DGAUM), the German Society for Hospital Hygiene (DGKH), the German Society for Pneumology and Respiratory Medicine (DGP), the German Mycological Society (DMykG), the Society for Pediatric Allergology and Environmental Medicine (GPA), the German Federal Association of Pediatric Pneumology (BAPP), and the Austrian Society for Medical Mycology (ÖGMM).

Authors:  Gerhard A Wiesmüller; Birger Heinzow; Ute Aurbach; Karl-Christian Bergmann; Albrecht Bufe; Walter Buzina; Oliver A Cornely; Steffen Engelhart; Guido Fischer; Thomas Gabrio; Werner Heinz; Caroline E W Herr; Jörg Kleine-Tebbe; Ludger Klimek; Martin Köberle; Herbert Lichtnecker; Thomas Lob-Corzilius; Rolf Merget; Norbert Mülleneisen; Dennis Nowak; Uta Rabe; Monika Raulf; Hans Peter Seidl; Jens-Oliver Steiß; Regine Szewszyk; Peter Thomas; Kerttu Valtanen; Julia Hurraß
Journal:  Allergo J Int       Date:  2017-02-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.