Literature DB >> 16570892

Delayed release of drain in total knee replacement reduces blood loss. A prospective randomised study.

Niloy Roy1, Matthew Smith, Mohammed Anwar, Christopher Elsworth.   

Abstract

Total knee arthroplasty is sometimes associated with major post-operative bleeding, often requiring transfusion. A prospective, randomised study was undertaken to assess the effect on post-operative bleeding of delaying release of the clamp on the suction drains. One hundred patients were allocated into two groups: Group A- immediate release of drain following release of tourniquet, and Group B- delayed release of the drain clamp by one hour. There was a statistically significant reduction (p = < 0.001) in postoperative bleeding between group A (1050 ml; 95%CI 728 - 1172 ml) compared to group B (732 ml; 95% CI 620- 845 ml). Average drop in corrected haemoglobin and postoperative transfusion requirement were also less in the delayed group. The results show that delaying release of the drains by one hour reduces postoperative blood loss and transfusion requirement following total knee arthroplasty.

Entities:  

Mesh:

Year:  2006        PMID: 16570892

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  16 in total

1.  Tranexamic acid reduces blood loss and blood transfusion after TKA: a prospective randomized controlled trial.

Authors:  Keerati Charoencholvanich; Pichet Siriwattanasakul
Journal:  Clin Orthop Relat Res       Date:  2011-04-22       Impact factor: 4.176

Review 2.  Non-continuous versus continuous wound drainage after total knee arthroplasty: a meta-analysis.

Authors:  Tao Li; Qianyu Zhuang; Xisheng Weng; Lei Zhou; Yanyan Bian
Journal:  Int Orthop       Date:  2013-09-19       Impact factor: 3.075

3.  No difference in total blood loss, haemoglobin and haematocrit between continues and intermittent wound drainage after total knee arthroplasty.

Authors:  Woon-Hwa Jung; Chung-Woo Chun; Ji-Hoon Lee; Jae-Hun Ha; Ji-Hye Kim; Jae-Heon Jeong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-10-23       Impact factor: 4.342

4.  Subcutaneous versus intraarticular indwelling closed suction drainage after TKA: a randomized controlled trial.

Authors:  Eun Seok Seo; Su Won Yoon; In Jun Koh; Chong Bum Chang; Tae Kyun Kim
Journal:  Clin Orthop Relat Res       Date:  2010-02-02       Impact factor: 4.176

5.  Temporary clamping of drain combined with tranexamic acid reduce blood loss after total knee arthroplasty: a prospective randomized controlled trial.

Authors:  Keerati Chareancholvanich; Pichet Siriwattanasakul; Rapeepat Narkbunnam; Chaturong Pornrattanamaneewong
Journal:  BMC Musculoskelet Disord       Date:  2012-07-20       Impact factor: 2.362

6.  Intra-articular injection of tranexamic acid via a drain plus drain-clamping to reduce blood loss in cementless total knee arthroplasty.

Authors:  Hirotaka Mutsuzaki; Kotaro Ikeda
Journal:  J Orthop Surg Res       Date:  2012-09-29       Impact factor: 2.359

7.  Postoperative blood loss reduction in computer-assisted surgery total knee replacement by low dose intra-articular tranexamic acid injection together with 2-hour clamp drain: a prospective triple-blinded randomized controlled trial.

Authors:  Paphon Sa-Ngasoongsong; Thanaphot Channoom; Viroj Kawinwonggowit; Patarawan Woratanarat; Pongsthorn Chanplakorn; Bussanee Wibulpolprasert; Siwadol Wongsak; Umaporn Udomsubpayakul; Supaporn Wechmongkolgorn; Nantaporn Lekpittaya
Journal:  Orthop Rev (Pavia)       Date:  2011-06-29

8.  The effect of drainage tube on bleeding and prognosis after total knee arthroplasty: a prospective cohort study.

Authors:  Xiao-Han Liu; Pei-Liang Fu; Shi-Ying Wang; Ya-Juan Yang; Gen-Di Lu
Journal:  J Orthop Surg Res       Date:  2014-04-23       Impact factor: 2.359

9.  Subcutaneous versus intraarticular closed suction indwelling drainage after total knee arthroplasty: A randomised control trial.

Authors:  Jae-Hyuk Yang; Jung-Ro Yoon; Anshul Dahuja; Seungyeop Song
Journal:  Indian J Orthop       Date:  2016 Jan-Feb       Impact factor: 1.251

10.  An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety.