Early application of an implantable loop recorder allows effective specific therapy in patients with recurrent suspected neurally mediated syncope.

Michele Brignole1, Richard Sutton, Carlo Menozzi, Roberto Garcia-Civera, Angel Moya, Wouter Wieling, Dietrich Andresen, David G Benditt, Panos Vardas.   

Abstract

AIMS: This prospective multicentre observational study assessed the efficacy of specific therapy based on implantable loop recorder (ILR) diagnostic observations in patients with recurrent suspected neurally mediated syncope (NMS). METHODS AND
RESULTS: Patients with three or more clinically severe syncopal episodes in the last 2 years without significant electrocardiographic and cardiac abnormalities were included. Orthostatic hypotension and carotid sinus syncope were excluded. After ILR implantation, patients were followed until the first documented syncope (Phase I). The ILR documentation of this episode determined the subsequent therapy and commenced Phase II follow-up. Among 392 patients, the 1-year recurrence rate of syncope during Phase I was 33%. One hundred and three patients had a documented episode and entered Phase II: 53 patients received specific therapy [47 a pacemaker because of asystole of a median 11.5 s duration and six anti-tachyarrhythmia therapy (catheter ablation: four, implantable defibrillator: one, anti-arrhythmic drug: one)] and the remaining 50 patients did not receive specific therapy. The 1-year recurrence rate in 53 patients assigned to a specific therapy was 10% (burden 0.07 +/- 0.2 episodes per patient/year) compared with 41% (burden 0.83 +/- 1.57 episodes per patient/year) in the patients without specific therapy (80% relative risk reduction for patients, P = 0.002, and 92% for burden, P = 0.002). The 1-year recurrence rate in patients with pacemakers was 5% (burden 0.05 +/- 0.15 episodes per patient/year). Severe trauma secondary to syncope relapse occurred in 2% and mild trauma in 4% of the patients.
CONCLUSION: A strategy based on early diagnostic ILR application, with therapy delayed until documentation of syncope allows a safe, specific, and effective therapy in patients with NMS.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16569653     DOI: 10.1093/eurheartj/ehi842

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  53 in total

1.  [From loss of consciousness to syncope].

Authors:  H-H Ebert; C Walter; H Volkmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-06

2.  Sleep syncope: treatment with a permanent pacemaker.

Authors:  Jason A Rytlewski; John T Lee; Satish R Raj
Journal:  Pacing Clin Electrophysiol       Date:  2012-03-20       Impact factor: 1.976

3.  Investigation of optimal position for implantable loop recorders by potential mapping with Reveal DX.

Authors:  Akira Kawashima; Fumi Tanimoto; Tsuyoshi Nagao; Takeshi Toyoshima; Yuji Okuyama
Journal:  J Arrhythm       Date:  2014-10-23

Review 4.  Diagnosis and treatment of syncope.

Authors:  Michele Brignole
Journal:  Heart       Date:  2007-01       Impact factor: 5.994

Review 5.  How to avoid a misdiagnosis in patients presenting with transient loss of consciousness.

Authors:  Sanjiv Petkar; Paul Cooper; Adam P Fitzpatrick
Journal:  Postgrad Med J       Date:  2006-10       Impact factor: 2.401

6.  [Reflex syncope : diagnosis and therapy].

Authors:  K Seidl; W von Scheidt; C Pfafferott
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-04-15

Review 7.  Current concepts in the evaluation and management of syncope.

Authors:  Vikas Kuriachan; Robert S Sheldon
Journal:  Curr Cardiol Rep       Date:  2008-09       Impact factor: 2.931

Review 8.  Renal nerve stimulation for treatment of neurocardiogenic syncope: a review from perspective of commercialization potential.

Authors:  B O'Brien; H Zafar; F Sharif
Journal:  Ir J Med Sci       Date:  2017-06-14       Impact factor: 1.568

9.  Implantable loop recorders in patients with unexplained syncope: Clinical predictors of pacemaker implantation.

Authors:  Martin Huemer; Ann-Kristin Becker; Alexander Wutzler; Philipp Attanasio; Abdul S Parwani; Philipp Lacour; Leif-Hendrik Boldt; Burkert Pieske; Wilhelm Haverkamp; Florian Blaschke
Journal:  Cardiol J       Date:  2018-02-05       Impact factor: 2.737

Review 10.  [Event-recorder].

Authors:  Andreas Schuchert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-10-25
View more