Literature DB >> 16568431

Gradient- and spin-echo T2-weighted imaging for SPIO-enhanced detection and characterization of focal liver lesions.

Takeshi Yoshikawa1, Donald G Mitchell, Shozo Hirota, Yoshiharu Ohno, Kazushige Oda, Takaki Maeda, Masahiko Fujii, Kazuro Sugimura.   

Abstract

PURPOSE: To evaluate superparamagnetic iron oxide (SPIO)-enhanced breathhold T2-weighted GRASE imaging in detection and characterization of focal liver lesions.
MATERIALS AND METHODS: In 30 patients (including 20 with cirrhosis) with 39 malignant and 25 benign lesions, gradient- and spin-echo (GRASE) images with two echo times (75 and 90 msec; GRASE75 and GRASE90) were obtained prior to and following administration of SPIO, and compared with respiratory-triggered and breathhold fast spin-echo (RT-FSE and BH-FSE) images. Two readers evaluated image quality and reviewed 240 liver segments for sensitivity and specificity. Signal-to-noise ratio (SNR), and its reduction in liver and spleen after administration of SPIO, and lesion-to-liver contrast-to-noise ratio (CNR) were measured.
RESULTS: Compared with RT-FSE and BH-FSE, GRASE reduced scan time by 77% to 82% and 21% to 27%, respectively. The image qualities with BH-FSE and GRASE75 were higher than with BH-FSE and GRASE90. BH-FSE showed higher specificity than RT-FSE and GRASE90, but otherwise there were no significant differences between pulse sequences for sensitivity or specificity. The mean SNR and CNR of the lesions with RT-FSE were significantly higher than with the other methods. SPIO-induced signal reduction of liver SNR was smallest with BH-FSE.
CONCLUSION: GRASE is faster and more sensitive to SPIO than FSE, but its sensitivity and specificity were slightly inferior to those of BH-FSE. Image quality is a current limitation. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16568431     DOI: 10.1002/jmri.20572

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Signal decay due to susceptibility-induced intravoxel dephasing on multiple air-filled cylinders: MRI simulations and experiments.

Authors:  François De Guio; Hugues Benoit-Cattin; Armel Davenel
Journal:  MAGMA       Date:  2008-06-25       Impact factor: 2.310

2.  Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE?

Authors:  Morikatsu Yoshida; Takeshi Nakaura; Taihei Inoue; Shota Tanoue; Sentaro Takada; Daisuke Utsunomiya; Shota Tsumagari; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2018-01-15       Impact factor: 5.315

3.  68Ga-Sienna+ for PET-MRI Guided Sentinel Lymph Node Biopsy: Synthesis and Preclinical Evaluation in a Metastatic Breast Cancer Model.

Authors:  Heli Savolainen; Alessia Volpe; Alkystis Phinikaridou; Michael Douek; Gilbert Fruhwirth; Rafael T M de Rosales
Journal:  Nanotheranostics       Date:  2019-06-06

4.  Small malignant hepatic tumor detection in gadolinium- and ferucarbotran-enhanced magnetic resonance imaging: does combining ferucarbotran-enhanced T2*-weighted gradient echo and T2-weighted turbo spin echo images have additive efficacy?

Authors:  Young Kon Kim; Young Hwan Lee; Hyo Sung Kwak; Chong Soo Kim; Young Min Han
Journal:  Korean J Radiol       Date:  2008 Nov-Dec       Impact factor: 3.500

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.