Bone remodelling around a cemented polyethylene cup. A longitudinal densitometry study.

N R Shetty1, A J Hamer, R M Kerry, I Stockley, R Eastell, J M Wilkinson.   

Abstract

The aims of this study were to examine the repeatability of measurements of bone mineral density (BMD) around a cemented polyethylene Charnley acetabular component using dual-energy x-ray absorptiometry and to determine the longitudinal pattern of change in BMD during the first 24 months after surgery. The precision of measurements of BMD in 19 subjects ranged from 7.7% to 10.8% between regions, using a four-region-of-interest model. A longitudinal study of 27 patients demonstrated a transient decrease in net pelvic BMD during the first 12 months, which recovered to baseline at 24 months. The BMD in the region medial to the dome of the component reduced by between 7% and 10% during the first three months, but recovered to approximately baseline values by two years. Changes in BMD in the pelvis around cemented acetabular components may be measured using dual-energy x-ray absorptiometry. Bone loss after insertion of a cemented Charnley acetabular component is small, transient and occurs mainly at the medial wall of the acetabulum. After two years, bone mass returns to baseline values, with a pattern suggesting a uniform transmission of load to the acetabulum.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16567778     DOI: 10.1302/0301-620X.88B4.16786

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

1.  Periprosthetic bone remodeling after 12 years differs in cemented and uncemented hip arthroplasties.

Authors:  Prakash Chandran; Mohammed Azzabi; Mark Andrews; John G Bradley
Journal:  Clin Orthop Relat Res       Date:  2011-10-21       Impact factor: 4.176

2.  Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study.

Authors:  Rajesh Ghosh
Journal:  J Orthop       Date:  2016-03-29

3.  Proximal tibial bone density is preserved after unicompartmental knee arthroplasty.

Authors:  Bradley I Richmond; Simon V Hadlow; Tim G Lynskey; Cameron G Walker; Jacob T Munro
Journal:  Clin Orthop Relat Res       Date:  2013-01-17       Impact factor: 4.176

4.  In vitro fatigue failure of cemented acetabular replacements: a hip simulator study.

Authors:  N P Zant; P Heaton-Adegbile; J G Hussell; J Tong
Journal:  J Biomech Eng       Date:  2008-04       Impact factor: 2.097

5.  Peri-acetabular bone mineral densityin total hip replacement.

Authors:  L Gauthier; L Dinh; P E Beaulé
Journal:  Bone Joint Res       Date:  2013-08-02       Impact factor: 5.853

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.