Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis.

Fernando Zarone1, Roberto Sorrentino, Tonino Traini, Donato Di lorio, Sergio Caputi.   

Abstract

OBJECTIVES: The present in vitro study aimed at evaluating the fracture resistance of both implant-supported screw- and cement-retained porcelain fused to metal (PFM) single crowns. A scanning electron microscope (SEM) evaluation of the mode of failure of the specimens was also performed.
METHODS: Forty PFM premolar-shaped identical single crowns were realized. The restorations were divided into two groups: cement-retained (group 1) and screw-retained (group 2) prostheses. Compressive loading tests and SEM fractographic analyses were performed. The data were statistically analysed by means of the Student's t-test, with a confidence interval of 95%.
RESULTS: The mean fracture load value was 1657 (+/-725) N in group 1 and 1281 (+/-747) N in group 2; the statistical analysis pointed out no significant differences between the two groups (p=0.115). The mean work at maximum load value was 0.775 (+/-0.619) J in group 1 and 0.605 (+/-0.526) J in group 2; the statistical analysis pointed out no significant differences between the two groups (p=0.355). All the samples were affected by cohesive fractures of the porcelain. Screw-retained crowns showed microcracks at the level of the occlusal access to the screw and extensive fractures in the whole thickness of the ceramics. On the contrary, cement-retained restorations were affected by less wide paramarginal fractures of the porcelain. SIGNIFICANCE: A stronger implant-prosthetic connection was noticed in cemented restorations group than in screw-retained single crowns. Even though negatively influenced by the presence of the occlusal access to the screw, the metal-ceramics bond can be considered predictable in both the implant-prosthetic connection systems analysed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16564081     DOI: 10.1016/j.dental.2005.10.013

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  15 in total

1.  Mechanical performance of cement- and screw-retained all-ceramic single crowns on dental implants.

Authors:  Matthias Obermeier; Oliver Ristow; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-07-15       Impact factor: 3.573

2.  Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses.

Authors:  Roberto Sorrentino; Giorgio De Simone; Stefano Tetè; Simona Russo; Fernando Zarone
Journal:  Clin Oral Investig       Date:  2011-06-11       Impact factor: 3.573

3.  A comparison of the mechanical proprieties of different types of primary tooth restorations: an in vitro study.

Authors:  Junhui Wang; Baize Zhang; Yujiang Chen; Lulu Wang; Yang Du; Xiaojing Wang
Journal:  Clin Oral Investig       Date:  2022-02-14       Impact factor: 3.573

4.  Stress distribution of multiple implant-supported prostheses: Photoelastic and strain gauge analyses of external hexagon and morse taper connections.

Authors:  Ana-Beatriz-Bueno-Carlini Bittencourt; Erica-de Oliveira-Paiva Rezende; Marcio Campaner; Sandro-Basso Bitencourt; Daniela-Micheline Dos Santos; Aldiéris-Alves Pesqueira; Marcelo-Coelho Goiato
Journal:  J Clin Exp Dent       Date:  2022-03-01

Review 5.  Properties of polyetheretheretherketone (PEEK) implant abutments: A systematic review.

Authors:  Romaisa Ghazal-Maghras; Jaime Vilaplana-Vivo; Fabio Camacho-Alonso; Yolanda Martínez-Beneyto
Journal:  J Clin Exp Dent       Date:  2022-04-01

6.  In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns.

Authors:  Martin Rosentritt; Sebastian Hahnel; Frank Engelhardt; Michael Behr; Verena Preis
Journal:  Clin Oral Investig       Date:  2016-07-01       Impact factor: 3.573

7.  The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns.

Authors:  Reza Derafshi; Mitra Farzin; Masoumeh Taghva; Hossein Heidary; Berivan Atashkar
Journal:  J Dent (Shiraz)       Date:  2015-03

8.  Knowledge and practice of implant-retained restorations among dental students in Saudi Arabia.

Authors:  Fahim Vohra; Altaf Hussain Shah; Mohammad Sohail Zafar; Zaheer Kola
Journal:  Pak J Med Sci       Date:  2015 Jul-Aug       Impact factor: 1.088

9.  A Special Design to Facilitate Retrieval of Cement-Retained Zirconia-Based Implant-Supported Restorations.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Masumeh Taghva
Journal:  J Dent (Shiraz)       Date:  2021-06

10.  3D-based buccal augmentation for ideal prosthetic implant alignment-an optimized method and report on 7 cases with pronounced buccal concavities.

Authors:  Hans-Joachim Nickenig; Maximilian Riekert; Matthias Zirk; Max-Philipp Lentzen; Joachim E Zöller; Matthias Kreppel
Journal:  Clin Oral Investig       Date:  2022-01-22       Impact factor: 3.606

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.