Literature DB >> 16563967

Is native aortic valve commissural fusion in patients with long-term left ventricular assist devices associated with clinically important aortic insufficiency?

George V Letsou1, John H Connelly, Reynolds M Delgado, Timothy J Myers, Igor D Gregoric, Frank W Smart, O H Frazier.   

Abstract

BACKGROUND: Long-term left ventricular assist device (LVAD) support diminishes flow through the native aortic valve and decreases valve motion. This may cause aortic valve commissural fusion. The clinical importance of such fusion is not well understood.
METHODS: Thirty-three consecutive patients receiving long-term LVAD support were followed up until transplantation or death. In each case, the native aortic valve was examined pathologically for commissural fusion. Pathology findings were correlated with hemodynamic performance as assessed by both LVAD pump flow and echocardiography.
RESULTS: Seventeen of the 33 patients had some degree of native aortic valve commissural fusion. Four patients had fusion at 2 commissures; of these, 2 had clinically significant native valve aortic insufficiency (2+ or greater), and 1 exhibited trace insufficiency of the native aortic valve. Thirteen patients had fusion at only 1 aortic commissure; of these, 2 had clinically significant aortic insufficiency (2+ or greater), and 3 had trace or mild (1+) insufficiency of native aortic valve. Two of the 4 patients with fusion at 2 commissures required increased LVAD support of >3 liters/min/cm2. No patient with fusion of only 1 commissure required increased LVAD support. Three patients with no commissural fusion of the aortic valve required increased LVAD support secondary to sepsis.
CONCLUSIONS: Commissural fusion of the native aortic valve occurs in a significant number of patients receiving long-term LVAD support and can necessitate increased levels of LVAD support. Recognition of this phenomenon may allow development of strategies to minimize commissural fusion and extend LVAD pump life.

Entities:  

Mesh:

Year:  2006        PMID: 16563967     DOI: 10.1016/j.healun.2005.11.451

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  8 in total

1.  Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device.

Authors:  Jerson R Martina; Marguerite E I Schipper; Nicolaas de Jonge; Faiz Ramjankhan; Roel A de Weger; Jaap R Lahpor; Aryan Vink
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-06-24

Review 2.  New Challenges in the Treatment of Patients With Left Ventricular Support: LVAD Thrombosis.

Authors:  Ann B Nguyen; Nir Uriel; Sirtaz Adatya
Journal:  Curr Heart Fail Rep       Date:  2016-12

Review 3.  Mechanical circulatory support: devices, outcomes and complications.

Authors:  Carmelo A Milano; Alan A Simeone
Journal:  Heart Fail Rev       Date:  2013-01       Impact factor: 4.214

4.  Development of a novel drive mode to prevent aortic insufficiency during continuous-flow LVAD support by synchronizing rotational speed with heartbeat.

Authors:  Yuichiro Kishimoto; Yoshiaki Takewa; Mamoru Arakawa; Akihide Umeki; Masahiko Ando; Takashi Nishimura; Yutaka Fujii; Toshihide Mizuno; Motonobu Nishimura; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-01-23       Impact factor: 1.731

5.  Aortic valve noncoronary cusp thrombosis after implantation of a nonpulsatile, continuous-flow pump.

Authors:  Zumrut T Demirozu; O H Frazier
Journal:  Tex Heart Inst J       Date:  2012

Review 6.  Why pulsatility still matters: a review of current knowledge.

Authors:  Davor Barić
Journal:  Croat Med J       Date:  2014-12       Impact factor: 1.351

7.  Patient-Specific Computational Fluid Dynamics Reveal Localized Flow Patterns Predictive of Post-Left Ventricular Assist Device Aortic Incompetence.

Authors:  Rohan Shad; Alexander D Kaiser; Sandra Kong; Robyn Fong; Nicolas Quach; Cayley Bowles; Patpilai Kasinpila; Yasuhiro Shudo; Jeffrey Teuteberg; Y Joseph Woo; Alison L Marsden; William Hiesinger
Journal:  Circ Heart Fail       Date:  2021-06-18       Impact factor: 10.447

8.  Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

Authors:  Selim Bozkurt; Frans N van de Vosse; Marcel C M Rutten
Journal:  J Med Biol Eng       Date:  2016-06-25       Impact factor: 1.553

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.