Literature DB >> 16563961

Functional phantom for fMRI: a feasibility study.

Ville Renvall1, Raimo Joensuu, Riitta Hari.   

Abstract

Functional magnetic resonance imaging (fMRI) reveals changes in blood oxygen level-dependent (BOLD) signal after considerable processing. This paper describes the implementation and testing of an fMRI phantom where electric current applied to a thin wire within a proton-rich medium substituted BOLD distortion of the magnetic field; the scanner detects these two distortions as practically identical signal changes. The magnitude of the change depended on the current strength. The phantom has a number of possible applications. Signal changes across sessions, days, instruments and individuals could be monitored. Placing the phantom close to a subject during an fMRI experiment could allow differentiating sensitivity changes in the scanner due to instrumentation from changes in the subject's state and performance during the experiment. The spatial extent of brain activations and effects of various changes in the chain of image formation could be analyzed using current-induced "activations". Furthermore, the phantom could expedite fMRI sequence development by reducing the need to scan human subjects, who introduce uncertainty to the signal. Thus, this fMRI phantom could be useful for both cognitive fMRI studies and scanner calibration.

Entities:  

Mesh:

Year:  2006        PMID: 16563961     DOI: 10.1016/j.mri.2005.07.012

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  Transients may occur in functional magnetic resonance imaging without physiological basis.

Authors:  Ville Renvall; Riitta Hari
Journal:  Proc Natl Acad Sci U S A       Date:  2009-11-16       Impact factor: 11.205

2.  Data quality in fMRI and simultaneous EEG-fMRI.

Authors:  Toni Ihalainen; Linda Kuusela; Sampsa Turunen; Sami Heikkinen; Sauli Savolainen; Outi Sipilä
Journal:  MAGMA       Date:  2014-04-26       Impact factor: 2.310

3.  Metal artifacts with dental implants: Evaluation using a dedicated CT/MR oral phantom with registration of the CT and MR images.

Authors:  Min-Young Lee; Kyu-Ho Song; Jeong-Woo Lee; Bo-Young Choe; Tae Suk Suh
Journal:  Sci Rep       Date:  2019-01-24       Impact factor: 4.379

4.  BOLD signal simulation and fMRI quality control base on an active phantom: a preliminary study.

Authors:  Tiao Chen; Yue Zhao; Chuntao Jia; Zilong Yuan; Jianfeng Qiu
Journal:  Med Biol Eng Comput       Date:  2020-02-08       Impact factor: 2.602

  4 in total