Literature DB >> 16563955

Quantitative MRI: a reliable protocol for measurement of cerebral gyrification using stereology.

Lisa Ronan1, Colin P Doherty, Norman Delanty, John Thornton, Mary Fitzsimons.   

Abstract

Stereology is a sampling technique used to generate mathematically unbiased estimates of geometric properties of three-dimensional structures based on two-dimensional slices of the object. Using this method, volume and surface area estimates may be generated in a robust, reliable and time-efficient manner based on magnetic resonance (MR) image data. We present a method of determining the isoperimetric ratio, which may be used as an index of gyrification of the human cerebrum, using stereological volume and surface area estimates applied to in vivo MR image data. This parameter may be of use in identifying subtle cortical developmental malformations in diseases such as epilepsy and schizophrenia. We also conduct a series of inter- and intrarater repeatability tests based on 20 normal brains, which demonstrated the reliability and robustness of stereological techniques.

Entities:  

Mesh:

Year:  2006        PMID: 16563955     DOI: 10.1016/j.mri.2005.10.033

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  8 in total

1.  Cerebellar asymmetry in a pair of monozygotic handedness-discordant twins.

Authors:  Richard Ewald Rosch; Lisa Ronan; Lynn Cherkas; Jennifer Mary Gurd
Journal:  J Anat       Date:  2010-07       Impact factor: 2.610

2.  Volumetric evaluation of the relations among the cerebrum, cerebellum and brain stem in young subjects: a combination of stereology and magnetic resonance imaging.

Authors:  Nihat Ekinci; Niyazi Acer; Akcan Akkaya; Seref Sankur; Taner Kabadayi; Bünyamin Sahin
Journal:  Surg Radiol Anat       Date:  2008-05-14       Impact factor: 1.246

3.  A stereological assessment method for estimating the surface area of cycloids.

Authors:  Bunyami Unal; Adem Kara; Selina Aksak; Deniz Unal
Journal:  Eurasian J Med       Date:  2010-08

4.  Stereological Evaluation of Tumor Regression Rates in Lung Cancer Using CT Via the Cavalieri Method.

Authors:  Metin Akgun; Mecit Kantarci; Kerim Cayir; Ummugulsum Bayraktutan; Selim Doganay; Omer Araz; Eyup Altunkaynak; Mehmet Bilici; Bunyami Unal; Metin Gorguner
Journal:  Eurasian J Med       Date:  2008-12

5.  Application of stereological estimates in patients with severe head injuries using CT and MR scanning images.

Authors:  N Eriksen; E Rostrup; K Andersen; M J Lauritzen; M Fabricius; V A Larsen; J P Dreier; A J Strong; J A Hartings; B Pakkenberg
Journal:  Br J Radiol       Date:  2009-08-18       Impact factor: 3.039

6.  MRI-based kidney volume measurements in ADPKD: reliability and effect of gadolinium enhancement.

Authors:  Kyongtae T Bae; Cheng Tao; Fang Zhu; James E Bost; Arlene B Chapman; Jared J Grantham; Vicente E Torres; Lisa M Guay-Woodford; Catherine M Meyers; William M Bennett
Journal:  Clin J Am Soc Nephrol       Date:  2009-04-01       Impact factor: 8.237

7.  Volume estimation of the thalamus using freesurfer and stereology: consistency between methods.

Authors:  Simon S Keller; Jan S Gerdes; Siawoosh Mohammadi; Christoph Kellinghaus; Harald Kugel; Katja Deppe; E Bernd Ringelstein; Stefan Evers; Wolfram Schwindt; Michael Deppe
Journal:  Neuroinformatics       Date:  2012-10

8.  Development and characterization of a Yucatan miniature biomedical pig permanent middle cerebral artery occlusion stroke model.

Authors:  Simon R Platt; Shannon P Holmes; Elizabeth W Howerth; Kylee Jo J Duberstein; C Robert Dove; Holly A Kinder; Emily L Wyatt; Amie V Linville; Vivian W Lau; Steven L Stice; William D Hill; David C Hess; Franklin D West
Journal:  Exp Transl Stroke Med       Date:  2014-03-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.