Literature DB >> 16558342

Intertester reliability of assessing postural sway using the chattecx balance system.

C G Mattacola, D A Lebsack, D H Perrin.   

Abstract

In this study, we examined intertester reliability of dynamic and static balance using the Chattecx Dynamic Balance System. Ten female and two male subjects were randomly assigned to two testers and completed ten, 10-second preprogrammed double- and single-leg test conditions. Balance was measured as postural sway in centimeters by the Chattecx Dynamic Balance System. Static balance consisted of the platform remaining stable, whereas dynamic balance consisted of the platform tilting in an anterior and posterior direction during testing. The protocols and average postural sway values were:1. Double-Leg Static Eyes Open ([unk] = .28 cm)2. Double-Leg Static Eyes Closed ([unk] = .37 cm)3. Double-Leg Dynamic Eyes Open ([unk] = .86 cm)4. Double-Leg Dynamic Eyes Closed ([unk] = 1.72 cm)5. Single-Leg Static Dominant Eyes Open ([unk] = .99 cm)6. Single-Leg Static Dominant Eyes Closed ([unk] = 1.70 cm)7. Single-Leg Static Nondominant Eyes Open ([unk] = .65 cm)8. Single-Leg Static Nondominant Eyes Closed ([unk] = 1.48 cm)9. Single-Leg Dynamic Dominant Eyes Open ([unk] = .99cm)10. Single-Leg Dynamic Nondominant Eyes Open ([unk] = .91 cm).The mean values of postural sway ranged from .28 cm to 1.72 cm for double-leg stance measures and from .65 cm to 1.70 cm for the single-leg stance measures. The intraclass correlations (ICCs)(2,1) ranged from poor to excellent (ICCs = .06 to .90) and the standard error of measurement (SEM) ranged from .06 to .34 for the 10 trials. We feel that variability exists between subjects and/or testers between trials. The wide range of reliability values suggests that further research should determine both intratester and intertester reliability using a variety of protocols for assessment of static and dynamic balance.

Entities:  

Year:  1995        PMID: 16558342      PMCID: PMC1317868     

Source DB:  PubMed          Journal:  J Athl Train        ISSN: 1062-6050            Impact factor:   2.860


  3 in total

1.  Reliability of ground reaction force measurements during dynamic transitions from bipedal to single-limb stance in healthy adults.

Authors:  T A Hanke; M W Rogers
Journal:  Phys Ther       Date:  1992-11

2.  Joint receptor contributions to reflexive and kinesthetic responses.

Authors:  R A Newton
Journal:  Phys Ther       Date:  1982-01

3.  Converting Chattecx Balance System vertical reaction force measurements to center of pressure excursion measurements.

Authors:  M D Grabiner; T M Lundin; J W Feuerbach
Journal:  Phys Ther       Date:  1993-05
  3 in total
  6 in total

1.  Effect of orthotics on postural sway after fatigue of the plantar flexors and dorsiflexors.

Authors:  D T Ochsendorf; C G Mattacola; B L Arnold
Journal:  J Athl Train       Date:  2000-01       Impact factor: 2.860

2.  Effect of prophylactic knee bracing on balance and joint position sense.

Authors:  T W Kaminski; D H Perrin
Journal:  J Athl Train       Date:  1996-04       Impact factor: 2.860

3.  Effects of a 6-week strength and proprioception training program on measures of dynamic balance: a single-case design.

Authors:  C G Mattacola; J W Lloyd
Journal:  J Athl Train       Date:  1997-04       Impact factor: 2.860

4.  Sensitivity of body sway parameters during quiet standing to manipulation of support surface size.

Authors:  Sarabon Nejc; Rosker Jernej; Stefan Loefler; Helmut Kern
Journal:  J Sports Sci Med       Date:  2010-09-01       Impact factor: 2.988

Review 5.  Efficacy of progressive resistance training on balance performance in older adults : a systematic review of randomized controlled trials.

Authors:  Rhonda Orr; Jacqui Raymond; Maria Fiatarone Singh
Journal:  Sports Med       Date:  2008       Impact factor: 11.136

6.  Resistive Exercise for Arthritic Cartilage Health (REACH): a randomized double-blind, sham-exercise controlled trial.

Authors:  Angela K Lange; Benedicte Vanwanseele; Nasim Foroughi; Michael K Baker; Ronald Shnier; Richard M Smith; Maria A Fiatarone Singh
Journal:  BMC Geriatr       Date:  2009-01-13       Impact factor: 3.921

  6 in total