Literature DB >> 16553150

Iohexol plasma clearance in healthy dogs and cats.

Isabelle Goy-Thollot1, Caroline Chafotte, Stéphane Besse, François Garnier, Paul Y Barthez.   

Abstract

Iohexol plasma clearance as a measure of glomerular filtration was determined in 31 dogs and 19 cats after an intravenous (i.v.) bolus injection. All animals were healthy and privately owned. Serial blood samples were taken before and up to 4 h after tracer injection. Iohexol plasma concentration was determined using X-ray fluorescence. A plasma tracer elimination curve was generated and clearance was calculated by dividing the injected dose by the area under the curve estimated using a two-compartment pharmacological model. Clearance was normalized to body weight (BW), body surface area (BSA), and extracellular fluid volume (ECFV). Mean, SD, and coefficient of variation of plasma clearance, before and after normalization, were calculated. Linear regression analyses were performed between body size and normalized plasma clearances. No significant linear relation was found between BSA and clearance normalized to BSA in dogs, and between BSA, BW, ECFV and clearance normalized to BSA, BW, and ECFV in cats. The optimal method for normalization of iohexol plasma clearance in dogs was by using BSA. In cats, all three methods tested were considered satisfactory. Normalization to BSA appears to be superior to normalization to BW and ECFV in dogs, and can be recommended for clinical use.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16553150     DOI: 10.1111/j.1740-8261.2006.00133.x

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  4 in total

Review 1.  An overview of glomerular filtration rate testing in dogs and cats.

Authors:  Vanessa E Von Hendy-Willson; Barrak M Pressler
Journal:  Vet J       Date:  2010-06-11       Impact factor: 2.688

2.  A Limited Sampling, Simple, and Useful Method for Determination of Glomerular Filtration Rate in Cats by Using a New Accurate HPLC Method to Measure Iohexol Plasmatic Concentrations.

Authors:  Meucci Valentina; Guidi Grazia; Melanie Pierre; Breghi Gloria; Lippi Ilaria
Journal:  J Vet Med       Date:  2013-11-12

3.  Relationship between serum iohexol clearance, serum SDMA concentration, and serum creatinine concentration in non-azotemic dogs.

Authors:  Myles McKenna; Ludovic Pelligand; Jonathan Elliott; Daniel Cotter; Rosanne Jepson
Journal:  J Vet Intern Med       Date:  2019-11-14       Impact factor: 3.333

4.  Clinical utility of estimation of glomerular filtration rate in dogs.

Authors:  Myles McKenna; Ludovic Pelligand; Jonathan Elliott; David Walker; Rosanne Jepson
Journal:  J Vet Intern Med       Date:  2019-08-02       Impact factor: 3.333

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.