Scatter factors in proton therapy with a broad beam.

T Akagi1, N Kanematsu, Y Takatani, H Sakamoto, Y Hishikawa, M Abe.   

Abstract

In the absence of a predictor of beam output in proton therapy using a broad beam, the beam output is obtained for individual treatments by calibrating the beam monitors. The calibration is carried out under conditions similar to the treatment conditions but with a phantom instead of the patient. However, the dose in the phantom a priori differs from that in the patient. In order to deliver the accurate dose, a correction factor has been introduced to correct the difference. This correction factor is referred to as a scatter factor in an analogy with photon therapy, and is defined as the ratio of the dose at the prescription point in the patient to the dose at the calibration point in the phantom. Under the calibration conditions at Hyogo Ion Beam Medical Center (HIBMC), the range compensator and the collimator, which are usually required in proton therapy with a broad beam, are not used. Therefore the scatter factor includes the effects of the devices as well as the difference between the dose in the patient and that in the phantom. We have developed an estimator using a dose calculation based on the pencil beam algorithm and implemented it in a treatment planning system (TPS) for clinical use. This estimator estimates the scatter factor by calculating the ratio of the doses under the same conditions in the TPS. In order to evaluate the performance of the estimator, demonstrations were carried out for cases with measurable outcomes using a gantry nozzle at HIBMC. We observed 2-3% differences between the measurements and the estimations. These differences were considered to result from the limitations of the dose calculation algorithm in modelling the beam and the patient.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16552114     DOI: 10.1088/0031-9155/51/7/020

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Comparability of three output prediction models for a compact passively double-scattered proton therapy system.

Authors:  Sven Ferguson; Yong Chen; Clara Ferreira; Mohammad Islam; Vance P Keeling; Andy Lau; Salahuddin Ahmad; Hosang Jin
Journal:  J Appl Clin Med Phys       Date:  2017-04-19       Impact factor: 2.102

2.  Investigation on Patient/Compensator Scatter Factor for Monitor Unit Calculation in Proton Therapy.

Authors:  Michael T Prusator; Salahuddin Ahmad; Yong Chen
Journal:  Int J Part Ther       Date:  2018-11-30

Review 3.  Charged particle radiotherapy at the Hyogo Ion Beam Medical Center: Characteristics, technology and clinical results.

Authors:  Mitsuyuki Abe
Journal:  Proc Jpn Acad Ser B Phys Biol Sci       Date:  2007-09       Impact factor: 3.493

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.