Literature DB >> 16547080

How effectively can clinical examination pick up congenital heart disease at birth?

C Patton1, E Hey.   

Abstract

AIMS: To assess what proportion of all cardiac abnormality can be suspected at birth when all clinical examination before discharge is undertaken by a small stable team of clinicians.
METHODS: A prospective audit of all the 14 572 births in a maternity unit only staffed by nurse practitioners between 1996 and 2003.
RESULTS: 1.2% of all babies born in the unit were found to have a structural defect (as confirmed by echocardiography) within a year of birth. The number not suspected before discharge declined over time, and only 6% were first suspected after discharge in the last four years of this eight year study. Four potentially life threatening conditions initially went unsuspected in 1996-8, but none after that. A policy of referring every term baby with a murmur at 1 day of age that was still present at 7-10 days resulted in 4.2% requiring cardiac referral; 54% of these babies still had a murmur when assessed one to two weeks later, and 33% had a structural defect. Parents said in independent, retrospectively conducted, interviews that they found it confidence building to have any possible heart defect identified early and the cause of any murmur clearly and authoritatively explained.
CONCLUSIONS: Effective screening requires experience and a clear, structured, referral pathway, but can work much better than most previous reports suggest. Whether staff bring a medical or nursing background to the task may well be of less importance.

Entities:  

Mesh:

Year:  2006        PMID: 16547080      PMCID: PMC2672726          DOI: 10.1136/adc.2005.082636

Source DB:  PubMed          Journal:  Arch Dis Child Fetal Neonatal Ed        ISSN: 1359-2998            Impact factor:   5.747


  27 in total

1.  Routine neonatal examination: effectiveness of trainee paediatrician compared with advanced neonatal nurse practitioner.

Authors:  T W Lee; R E Skelton; C Skene
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2001-09       Impact factor: 5.747

2.  Neonatal murmurs: are senior house officers good enough?

Authors:  K F M Farrer; J M Rennie
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-03       Impact factor: 5.747

3.  Evaluating a nurse-led model for providing neonatal care.

Authors: 
Journal:  J Adv Nurs       Date:  2004-07       Impact factor: 3.187

Review 4.  Routine examination of the newborn: the EMREN study. Evaluation of an extension of the midwife role including a randomised controlled trial of appropriately trained midwives and paediatric senior house officers.

Authors:  J Townsend; D Wolke; J Hayes; S Davé; C Rogers; L Bloomfield; E Quist-Therson; M Tomlin; D Messer
Journal:  Health Technol Assess       Date:  2004-04       Impact factor: 4.014

Review 5.  Early diagnosis of congenital heart disease.

Authors:  S Richmond; C Wren
Journal:  Semin Neonatol       Date:  2001-02

6.  Opening Pandora's box: parental anxiety and the assessment of childhood murmurs.

Authors:  R M Giuffre; I Walker; S Vaillancourt; S Gupta
Journal:  Can J Cardiol       Date:  2002-04       Impact factor: 5.223

7.  Effectiveness of pulse oximetry screening for congenital heart disease in asymptomatic newborns.

Authors:  Robert I Koppel; Charlotte M Druschel; Tonia Carter; Barry E Goldberg; Prabhu N Mehta; Rohit Talwar; Fredrick Z Bierman
Journal:  Pediatrics       Date:  2003-03       Impact factor: 7.124

8.  Temporal variability in birth prevalence of congenital heart defects as recorded by a general birth defects registry.

Authors:  Giuliano Bosi; Giampaolo Garani; Marco Scorrano; Elisa Calzolari
Journal:  J Pediatr       Date:  2003-06       Impact factor: 4.406

Review 9.  The incidence of congenital heart disease.

Authors:  Julien I E Hoffman; Samuel Kaplan
Journal:  J Am Coll Cardiol       Date:  2002-06-19       Impact factor: 24.094

10.  Routine pulse oximetry in the asymptomatic newborn.

Authors:  S Richmond; G Reay; M Abu Harb
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-09       Impact factor: 5.747

View more
  5 in total

Review 1.  How effectively can clinical examination pick up congenital heart disease at birth?

Authors:  O C Onuzo
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-07       Impact factor: 5.747

Review 2.  Should pulse oximetry be used to screen for congenital heart disease?

Authors:  Pekka Valmari
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-05       Impact factor: 5.747

Review 3.  Management of asymptomatic cardiac murmurs in term neonates.

Authors:  Asha Shenvi; Jyoti Kapur; Shree Vishna Rasiah
Journal:  Pediatr Cardiol       Date:  2013-03-10       Impact factor: 1.655

4.  Implementation of Congenital Heart Diseases Screening at the Bihac Cantonal Hospital.

Authors:  Mediha Kardasevic; Ida Jovanovic; Jelica Predojevic Samardzic
Journal:  Mater Sociomed       Date:  2017-03

5.  Clinical score to detect congenital heart defects: Concept of second screening.

Authors:  Fazil M Izhar; Shaad Abqari; Tabassum Shahab; Syed Manazir Ali
Journal:  Ann Pediatr Cardiol       Date:  2020-09-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.