Literature DB >> 16545960

Enhanced MALDI ionization efficiency at the metal-matrix interface: practical and mechanistic consequences of sample thickness and preparation method.

Gregor McCombie1, Richard Knochenmuss.   

Abstract

Electrosprayed spots of varying thickness were evaluated for use as reproducible, homogenous, high efficiency MALDI samples. Thin samples on stainless steel plates were found to give exceptionally strong signals, as did the last layers of thick samples, when ablated down to the steel substrate. A small enhancement was also observed for thin samples on a gold substrate, and with a few-nanometer gold coating on top of a thick sample. Ion yields and intensity ratios can be understood in the context of the previously described quantitative MALDI model including the matrix-metal interfacial ionization potential reduction effect (Knochenmuss, R.; Anal. Chem. 2004, 76, 3179-3184). The absolute and relative stabilities of ion signals were found to be at least a factor of two better for the thin electrosprayed spots, compared to spots prepared by dried droplet methods.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16545960     DOI: 10.1016/j.jasms.2006.02.005

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  19 in total

1.  Heterogeneity within MALDI samples as revealed by mass spectrometric imaging.

Authors:  R W Garden; J V Sweedler
Journal:  Anal Chem       Date:  2000-01-01       Impact factor: 6.986

2.  Secondary ion-molecule reactions in matrix-assisted laser desorption/ionization

Authors: 
Journal:  J Mass Spectrom       Date:  2000-11       Impact factor: 1.982

3.  MALDI ionization: the role of in-plume processes.

Authors:  R Knochenmuss; R Zenobi
Journal:  Chem Rev       Date:  2003-02       Impact factor: 60.622

4.  A quantitative model of ultraviolet matrix-assisted laser desorption/ionization including analyte ion generation.

Authors:  Richard Knochenmuss
Journal:  Anal Chem       Date:  2003-05-15       Impact factor: 6.986

5.  Photoionization pathways and free electrons in UV-MALDI.

Authors:  Richard Knochenmuss
Journal:  Anal Chem       Date:  2004-06-01       Impact factor: 6.986

6.  Gold coating of non-conductive membranes before matrix-assisted laser desorption/ionization tandem mass spectrometric analysis prevents charging effect.

Authors:  Alexander Scherl; Catherine G Zimmermann-Ivol; Joel Di Dio; Ali R Vaezzadeh; Pierre-Alain Binz; Michel Amez-Droz; Roland Cochard; Jean-Charles Sanchez; Matthias Glückmann; Denis F Hochstrasser
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

7.  Exciton mobility and trapping in a MALDI matrix.

Authors:  Patrick D Setz; Richard Knochenmuss
Journal:  J Phys Chem A       Date:  2005-05-12       Impact factor: 2.781

8.  Electrospray sample preparation for improved quantitation in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Authors:  R R Hensel; R C King; K G Owens
Journal:  Rapid Commun Mass Spectrom       Date:  1997       Impact factor: 2.419

9.  Molecular imaging of amyloid beta peptides in mouse brain sections using mass spectrometry.

Authors:  Markus Stoeckli; Dieter Staab; Matthias Staufenbiel; Karl-Heinz Wiederhold; Luca Signor
Journal:  Anal Biochem       Date:  2002-12-01       Impact factor: 3.365

10.  Analysis of the lipid composition of bull spermatozoa by MALDI-TOF mass spectrometry--a cautionary note.

Authors:  Jürgen Schiller; Karin Müller; Rosemarie Süss; Jürgen Arnhold; Claudia Gey; Andreas Herrmann; Jacqueline Lessig; Klaus Arnold; Peter Müller
Journal:  Chem Phys Lipids       Date:  2003-11       Impact factor: 3.329

View more
  9 in total

1.  Compelling evidence for Lucky Survivor and gas phase protonation: the unified MALDI analyte protonation mechanism.

Authors:  Thorsten W Jaskolla; Michael Karas
Journal:  J Am Soc Mass Spectrom       Date:  2011-03-08       Impact factor: 3.109

2.  Liquid matrix deposition on conductive hydrophobic surfaces for tuning and quantitation in UV-MALDI mass spectrometry.

Authors:  Magnus Palmblad; Rainer Cramer
Journal:  J Am Soc Mass Spectrom       Date:  2007-01-16       Impact factor: 3.109

3.  Comparison between vacuum sublimed matrices and conventional dried droplet preparation in MALDI-TOF mass spectrometry.

Authors:  Thorsten W Jaskolla; Michael Karas; Udo Roth; Kerstin Steinert; Christoph Menzel; Karsten Reihs
Journal:  J Am Soc Mass Spectrom       Date:  2009-02-12       Impact factor: 3.109

4.  Matrix segregation as the major cause for sample inhomogeneity in MALDI dried droplet spots.

Authors:  Stefan J Gabriel; Clemens Schwarzinger; Bettina Schwarzinger; Ulrich Panne; Steffen M Weidner
Journal:  J Am Soc Mass Spectrom       Date:  2014-04-30       Impact factor: 3.109

5.  Ion yields for some salts in MALDI: mechanism for the gas-phase ion formation from preformed ions.

Authors:  Jeong Hee Moon; Young Sik Shin; Yong Jin Bae; Myung Soo Kim
Journal:  J Am Soc Mass Spectrom       Date:  2011-11-03       Impact factor: 3.109

Review 6.  Mass spectrometry imaging and profiling of single cells.

Authors:  Eric J Lanni; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  J Proteomics       Date:  2012-03-29       Impact factor: 4.044

7.  Glycan analysis by isobaric aldehyde reactive tags and mass spectrometry.

Authors:  Shuang Yang; Wei Yuan; Weiming Yang; Jianying Zhou; Robert Harlan; James Edwards; Shuwei Li; Hui Zhang
Journal:  Anal Chem       Date:  2013-08-12       Impact factor: 6.986

8.  Ion Yields in the Coupled Chemical and Physical Dynamics Model of Matrix-Assisted Laser Desorption/Ionization.

Authors:  Richard Knochenmuss
Journal:  J Am Soc Mass Spectrom       Date:  2015-08-12       Impact factor: 3.109

9.  Microbowls with Controlled Concavity for Accurate Microscale Mass Spectrometry.

Authors:  Linfeng Xu; Xiangpeng Li; Wenzong Li; Kai-Chun Chang; Hyunjun Yang; Nannan Tao; Pengfei Zhang; Emory M Payne; Cyrus Modavi; Jacqueline Humphries; Chia-Wei Lu; Adam R Abate
Journal:  Adv Mater       Date:  2022-02-10       Impact factor: 32.086

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.