Saeid Azizian1, Bahare Yahyaei.
Abstract
Granular activated carbon was used for the removal of 18-crown-6 from aqueous solution by adsorption. The influence of two experimental parameters, initial 18-crown-6 concentration and temperature, on the adsorption kinetics was evaluated. The kinetics data obtained were modeled by pseudo-first-order and pseudo-second-order models, respectively. The process of adsorption follows a pseudo-second-order rate model. The most important result of the present study is that the correlation coefficient is not a sufficient criterion for selection of a kinetic model, and therefore several criteria are suggested for its selection.Entities:
Year: 2006 PMID: 16545832 DOI: 10.1016/j.jcis.2006.01.058
Source DB: PubMed Journal: J Colloid Interface Sci ISSN: 0021-9797 Impact factor: 8.128