Literature DB >> 16542690

The Partec CyFlow Counter could provide an option for CD4+ T-cell monitoring in the context of scaling-up antiretroviral treatment at the district level in Malawi.

M Fryland1, P Chaillet, R Zachariah, A Barnaba, L Bonte, R Andereassen, S Charrondière, R Teck, O Didakus.   

Abstract

A study was conducted in rural Malawi to verify (a) whether the Partec CyFlow Counter((R)) for CD4+ T-cell lymphocyte counting in HIV-positive individuals could be introduced into a district hospital laboratory and (b) whether it would produce CD4 counts of acceptable quality. CD4+ cell counting was performed using the Partec CyFlow Counter and the results were compared with a reference method (FACsCount). A total of 311 blood samples were analysed and the correlation coefficient for the CyFlow Counter was 0.92 (95% CI 0.89-0.95). Mean CD4 counts using the Partec and the reference methods were 308.2 cells/microl and 316.9 cells/microl, respectively. The mean difference in CD4 count values was -8.68 cells/microl (95% CI -18.8 to 1.4). Mean intra-run variation was -6.84 cells/microl (95% CI -12.9 to 0.79). In the district laboratory setting, the instrument could accommodate up to 75 blood samples per technician per day. After being trained, local laboratory staff found the CyFlow Counter procedures simple to run and the instrument easy to manipulate. The Partec CyFlow Counter produces sufficiently reliable results and the instrument appears robust under field conditions. It could provide a new option for introducing routine CD4+ cell monitoring at the district level in the context of scaling-up antiretroviral therapy in Malawi.

Entities:  

Mesh:

Year:  2006        PMID: 16542690     DOI: 10.1016/j.trstmh.2005.11.014

Source DB:  PubMed          Journal:  Trans R Soc Trop Med Hyg        ISSN: 0035-9203            Impact factor:   2.184


  11 in total

1.  Stool antigen immunodetection for diagnosis of Giardia duodenalis infection in human subjects with HIV and cancer.

Authors:  Maryam Nooshadokht; Behjat Kalantari-Khandani; Iraj Sharifi; Hossein Kamyabi; Namal P M Liyanage; Laurel A Lagenaur; Martin F Kagnoff; Steven M Singer; Zahra Babaei; Shahram Solaymani-Mohammadi
Journal:  J Microbiol Methods       Date:  2017-07-14       Impact factor: 2.363

2.  Estimating the need for antiretroviral treatment and an assessment of a simplified HIV/AIDS case definition in rural Malawi.

Authors:  Nuala McGrath; Katharina Kranzer; Jacqueline Saul; Amelia C Crampin; Simon Malema; Lackson Kachiwanda; Basia Zaba; Andreas Jahn; Paul Em Fine; Judith R Glynn
Journal:  AIDS       Date:  2007-11       Impact factor: 4.177

Review 3.  Low-cost assays for monitoring HIV infected individuals in resource-limited settings.

Authors:  Pachamuthu Balakrishnan; Hussain Syed Iqbal; Saravanan Shanmugham; Janardhanan Mohanakrishnan; Sunil S Solomon; Kenneth H Mayer; Suniti Solomon
Journal:  Indian J Med Res       Date:  2011-12       Impact factor: 2.375

4.  Affordable flow cytometry for enumeration of absolute CD4+ T-lymphocytes to identify subtype C HIV-1 infected adults requiring antiretroviral therapy (ART) and monitoring response to ART in a resource-limited setting.

Authors:  Lynn S Zijenah; Gerard Kadzirange; Simon Madzime; Margaret Borok; Chiedza Mudiwa; Ocean Tobaiwa; Mary Mucheche; Simbarashe Rusakaniko; David A Katzenstein
Journal:  J Transl Med       Date:  2006-08-14       Impact factor: 5.531

5.  Laboratory and field evaluation of the Partec CyFlow miniPOC for absolute and relative CD4 T-cell enumeration.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Abdoul Aziz Diallo; Souleymane Mboup; Tandakha Ndiaye Dieye; Luc Kestens
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

6.  WHO multicenter evaluation of FACSCount CD4 and Pima CD4 T-cell count systems: instrument performance and misclassification of HIV-infected patients.

Authors:  Djibril Wade; Géraldine Daneau; Said Aboud; Gaby H Vercauteren; Willy S K Urassa; Luc Kestens
Journal:  J Acquir Immune Defic Syndr       Date:  2014-08-15       Impact factor: 3.731

Review 7.  CD4 enumeration technologies: a systematic review of test performance for determining eligibility for antiretroviral therapy.

Authors:  Rosanna W Peeling; Kimberly A Sollis; Sarah Glover; Suzanne M Crowe; Alan L Landay; Ben Cheng; David Barnett; Thomas N Denny; Thomas J Spira; Wendy S Stevens; Siobhan Crowley; Shaffiq Essajee; Marco Vitoria; Nathan Ford
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

8.  CD4 T-cell enumeration in a field setting: evaluation of CyFlow counter using the CD4 easy count kit-dry and Pima CD4 systems.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Makhtar Camara; Tandakha Ndiaye Dieye; Souleymane Mboup; Luc Kestens
Journal:  PLoS One       Date:  2013-09-16       Impact factor: 3.240

9.  Affordable pediatric CD4 counting by flow cytometry in Malawi.

Authors:  Calman A Maclennan; Felix Dzumani; Alinane Namarika; Peter Moons; Edward Senga; Malcolm E Molyneux; Mark T Drayson; James E G Bunn
Journal:  Cytometry B Clin Cytom       Date:  2008       Impact factor: 3.058

10.  Performance Evaluation of the Becton Dickinson FACSPresto™ Near-Patient CD4 Instrument in a Laboratory and Typical Field Clinic Setting in South Africa.

Authors:  Lindi-Marie Coetzee; Keshendree Moodley; Deborah Kim Glencross
Journal:  PLoS One       Date:  2016-05-25       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.