Literature DB >> 16541841

A force reproduction analysis of two recording sensors of a computerized occlusal analysis system.

Robert B Kerstein1, Mark Lowe, Mike Harty, John Radke.   

Abstract

The purpose of this study was to measure the performance of a new design of occlusal sensor, the high definition (HD) sensor, and directly compare this sensor to the previous design. This new HD sensor design has increased active recording area by 33%, and decreased inactive recording area by 50% as compared to the previous design (G3). This was accomplished by determining the force reproduction variability for repeated occlusal closures on the same sensor for a sampling of sensors from both designs. Thirty (30) G3 and 30 HD sensors were consistently positioned and loaded 24 times between articulated epoxy casts by a Pneumatic Occlusal Force Simulator. Their force reproduction consistency was measured as an electronic voltage drop across six occlusal contacts that were consistently located on all sensors. The force variability of the two sensor designs was determined by comparing the consistency of the voltage drops across the six occlusal contacts. An analysis of variance was employed to determine the variability of force reproduction over multiple closures across six occlusal contact regions. For five of the six contacts, the G3 sensor mean variances, were significantly larger (p < 0.05) than those of the HD sensor. The within sensor variability of the HD sensor was significantly less than that of the G3 sensor. Within the limitations of this study, the HD sensor exhibited less variable force reproduction than the G3 sensor for at least 20 in-laboratory loading cycles.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16541841     DOI: 10.1179/crn.2006.004

Source DB:  PubMed          Journal:  Cranio        ISSN: 0886-9634            Impact factor:   2.020


  14 in total

Review 1.  Bite Force Recording Devices - A Review.

Authors:  Tarun Prakash Verma; Kanteshwari Iranagouda Kumathalli; Vinay Jain; Rajesh Kumar
Journal:  J Clin Diagn Res       Date:  2017-09-01

2.  Comparison of articulating paper markings and T Scan III recordings to evaluate occlusal force in normal and rehabilitated maxillofacial trauma patients.

Authors:  I P Majithia; Vimal Arora; S Anil Kumar; Vivek Saxena; Manish Mittal
Journal:  Med J Armed Forces India       Date:  2014-11-22

3.  Relationship between articulation paper mark size and percentage of force measured with computerized occlusal analysis.

Authors:  Sarah Qadeer; Robert Kerstein; Ryan Jin Yung Kim; Jung-Bo Huh; Sang-Wan Shin
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

4.  Electromyographic and patient-reported outcomes of a computer-guided occlusal adjustment performed on patients suffering from chronic myofascial pain.

Authors:  Abraham Dib; Javier Montero; José-Miguel Sanchez; Antonio López-Valverde
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-03-01

5.  Change of distribution and timing of bite force after botulinum toxin type A injection evaluated by a computerized occlusion analysis system.

Authors:  Ji Hee Song; Eunae S Cho; Seong Taek Kim; Hyung Joon Ahn
Journal:  Yonsei Med J       Date:  2014-07       Impact factor: 2.759

6.  Assessment of occlusion with the T-Scan system in patients undergoing orthognathic surgery.

Authors:  Jimoh Olubanwo Agbaje; Elke Van de Casteele; Ahmed S Salem; Dickson Anumendem; Eman Shaheen; Yi Sun; Constantinus Politis
Journal:  Sci Rep       Date:  2017-07-13       Impact factor: 4.379

7.  Clinical Decision Support Model to Predict Occlusal Force in Bruxism Patients.

Authors:  Bhornsawan Thanathornwong; Siriwan Suebnukarn
Journal:  Healthc Inform Res       Date:  2017-10-31

8.  Disclusion time reduction therapy in treating occluso-muscular pains.

Authors:  Prafulla Thumati; Robert B Kerstein; Roshan P Thumati
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

9.  Determining a relationship between applied occlusal load and articulating paper mark area.

Authors:  Jason P Carey; Mark Craig; Robert B Kerstein; John Radke
Journal:  Open Dent J       Date:  2007-07-23

10.  Computerized analysis of occlusal contacts in bruxism patients treated with occlusal splint therapy.

Authors:  Hasan Önder Gümüş; Halil İbrahim Kılınç; Süleyman Hakan Tuna; Nihal Ozcan
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.