Literature DB >> 16541412

Determination of MK-0431 in human plasma using high turbulence liquid chromatography online extraction and tandem mass spectrometry.

Wei Zeng1, Donald G Musson, Alison L Fisher, Amy Qiu Wang.   

Abstract

A robust and sensitive method using high turbulence liquid chromatography (HTLC) online extraction with tandem mass spectrometry (MS/MS) for the determination of MK-0431 in human plasma was developed and validated to support the clinical studies. This HTLC online extraction method eliminated the time-consuming offline sample extraction procedures and significantly increased productivity. A narrow bore large particle size reversed-phase column (Cyclone, 50 x 1.0 mm, 60 microm) and a BDS Hypersil C18 column (30 x 2.1 mm, 3 microm) were used as extraction and analytical columns, respectively. The linear dynamic range of the calibration curve was 0.5 to 1000 ng/mL. Intraday validation was conducted using five calibration curves prepared in five lots of human control plasma, and the intraday precision (RSD%) was from 2.4 to 9.0% and the accuracy was from 98.0 to 103% of the nominal value. The intraday precision (RSD%, n = 5) for plasma quality control (QC) samples varied from 2.0 to 5.3% and accuracy from 103 to 105% of the nominal value. The interday precision (RSD%) for 100 sets of plasma QC samples in 29 analytical runs varied from 6.3 to 9.0% and the accuracy from 98.8 to 104% of the nominal value. No significant difference was observed between the interday and intraday precision and accuracy of the QC samples. Copyright 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16541412     DOI: 10.1002/rcm.2426

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Evaluation of pharmacokinetic parameters and dipeptidyl peptidase-4 inhibition following single doses of sitagliptin in healthy, young Japanese males.

Authors:  Gary A Herman; Goutam C Mistry; Bingming Yi; Arthur J Bergman; Amy Q Wang; Wei Zeng; Li Chen; Karen Snyder; Jon L Ruckle; Patrick J Larson; Michael J Davies; Ronald B Langdon; Keith M Gottesdiener; John A Wagner
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

Review 2.  Determination of carryover and contamination for mass spectrometry-based chromatographic assays.

Authors:  Nicola C Hughes; Ernest Y K Wong; Juan Fan; Navgeet Bajaj
Journal:  AAPS J       Date:  2007-11-02       Impact factor: 4.009

3.  Comparison of conventional and supported liquid extraction methods for the determination of sitagliptin and simvastatin in rat plasma by LC-ESI-MS/MS.

Authors:  B Ramesh; N Manjula; S R Bijargi; V U M Sarma; P Sita Devi
Journal:  J Pharm Anal       Date:  2014-12-02